Influence of short-term venous stasis on clinical chemistry testing

被引:64
作者
Lippi, G [1 ]
Salvagno, GL [1 ]
Montagnana, M [1 ]
Brocco, G [1 ]
Guidi, GC [1 ]
机构
[1] Univ Verona, Ist Chim & Microscopia Clin, Dipartimento Sci Morfol Biomed, I-37100 Verona, Italy
关键词
blood collection; laboratory testing; pre-analytical variability; standardization tourniquet; venous stasis;
D O I
10.1515/CCLM.2005.146
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Control and standardization of preanalytical variability is a critical factor for achieving accuracy and precision in laboratory testing. Although venous stasis from tourniquet placement during venepuncture should be minimized, as it has been claimed to account for spurious and significant variations for several analytes in plasma, there is controversy surrounding. its real impact on laboratory testing. The aim of the present study was the investigation of the influence of short-term venous stasis on routine biochemical testing, by measuring the plasma concentration of 12 common analytes, including proteins, protein-bound substances, enzymes and electrolytes, in plasma specimens collected either without venous stasis or following the application of standardized external pressure of 60 mm Hg using a sphygmomanometer for 1 and 3 min. Although the overall correlation between measures was acceptable, the pattern of change was mostly dependent on the length of stasis, size and protein-binding characteristics of the analytes, achieving clinical significance for albumin, calcium and potassium after 1-min stasis, and alanine aminotransferase, albumin, calcium, chloride, total cholesterol, glucose and potassium after 3-min stasis. Statistically significant differences could be observed in seven (alanine aminotransferase, albumin, calcium, total cholesterol, creatine kinase, iron and potassium) and ten (alanine aminotransferase, albumin, calcium, chloride, total cholesterol, creatine kinase, creatinine, glucose, iron and potassium) out of the 12 analytes tested, after 1-and 3-min venous stasis, respectively. The most clinically significant changes from standard venepuncture, when compared to the current analytical quality specifications for desirable bias, occurred for potassium (1-min stasis, -2.8%; 3-min stasis, -4.8%, both p < 0.001), calcium (1-min stasis, +11.13%, p < 0.05; 3min stasis, +3.6%, p < 0.001) and albumin (1-min stasis, +3.5%; 3-min stasis, +8.6%, both p < 0.001). As most of these effects are dependent on the stasis time during venepuncture and biochemical or physiological characteristics of the analyte, these variations could likely be anticipated, allowing the most appropriate preventive measures to be adopted.
引用
收藏
页码:869 / 875
页数:7
相关论文
共 13 条
[1]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[2]  
Bonini P, 2002, CLIN CHEM, V48, P691
[3]  
BUFFINGTON S, 1996, NURSING PROCEDURES, P135
[4]  
DITTMANN M, 2001, BLOOD COLLECTION TEC, P1
[5]   A COMPARISON OF METHODS OF BLOOD WITHDRAWAL AND SAMPLE PREPARATION FOR POTASSIUM MEASUREMENTS [J].
HILL, AB ;
NAHRWOLD, ML ;
NOONAN, D ;
NORTHROP, P .
ANESTHESIOLOGY, 1980, 53 (01) :60-63
[6]   STANDARDIZATION OF OBTAINING BLOOD-SAMPLES - INFLUENCE OF TOURNIQUET APPLICATION ON 33 CONSTITUENTS OF BLOOD AND SERUM [J].
JUNGE, B ;
HOFFMEISTER, H ;
FEDDERSEN, HM ;
ROCKER, L .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1978, 103 (06) :260-265
[7]  
KANG H J, 1992, Yonsei Medical Journal, V33, P153
[8]   VENIPUNCTURE FOR CALCIUM ASSAYS - SHOULD WE STILL AVOID THE TOURNIQUET [J].
MCMULLAN, AD ;
BURNS, J ;
PATERSON, CR .
POSTGRADUATE MEDICAL JOURNAL, 1990, 66 (777) :547-548
[9]   GROSS ERRORS MADE BY ROUTINE BLOOD-SAMPLING FROM 2 SITES USING A TOURNIQUET APPLIED AT DIFFERENT POSITIONS [J].
MCNAIR, P ;
NIELSEN, SL ;
CHRISTIANSEN, C ;
AXELSSON, C .
CLINICA CHIMICA ACTA, 1979, 98 (1-2) :113-118
[10]   Towards quality specifications in extra-analytical phases of laboratory activity [J].
Plebani, M .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2004, 42 (06) :576-577