Embedded MR fluoroscopy: High temporal resolution real-time imaging during high spatial resolution 3D MRA acquisition

被引:13
作者
Fain, SB
Riederer, SJ
Huston, J
King, BF
机构
[1] Univ Wisconsin, Ctr Clin Sci E3 311, Dept Med Phys, Madison, WI 53792 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN USA
关键词
MR fluoroscopy; real-time MRI; contrast-enhanced 3D MR angiography; vascular MRI; perfusion MRI;
D O I
10.1002/mrm.1247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method termed "embedded fluoroscopy" for simultaneously acquiring a real-time sequence of 2D images during acquisition of a 3D image is presented. The 2D images are formed by periodically sampling the central phase encodes of the slab-select direction during the 3D acquisition. The tradeoffs in spatial and temporal resolution are quantified by two parameters: the "redundancy" (R), the fraction of the 3D acquisition sampled more than once; and the "effective temporal resolution" (T), the time between temporal updates of the central views. The method is applied to contrast-enhanced MR angiography (CE-MRA). The contrast bolus dynamics are portrayed in real time in the 2D image sequence while a high-resolution 3D image is being acquired. The capability of the 2D acquisition to measure contrast enhancement with only a 5% degradation of the spatial resolution of the 3D CE-MR angiogram is shown theoretically, The method is tested clinically in 15 CE-MRA patient studies of the carotid and renal arteries. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:690 / 698
页数:9
相关论文
共 24 条
[1]  
Busse RF, 1999, MAGNET RESON MED, V42, P69, DOI 10.1002/(SICI)1522-2594(199907)42:1<69::AID-MRM11>3.0.CO
[2]  
2-Y
[3]   Cardiac magnetic resonance fluoroscopy [J].
Debbins, JP ;
Riederer, SJ ;
Rossman, PJ ;
Grimm, RC ;
Felmlee, JP ;
Breen, JF ;
Ehman, RL .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :588-595
[4]   Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation [J].
Earls, JP ;
DeSena, S ;
Bluemke, DA .
RADIOLOGY, 1998, 209 (03) :844-849
[5]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[6]  
Fain SB, 1999, MAGNET RESON MED, V42, P1106, DOI 10.1002/(SICI)1522-2594(199912)42:6<1106::AID-MRM15>3.0.CO
[7]  
2-Q
[8]  
Fain SB, 1998, RADIOLOGY, V209P, P356
[9]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[10]   Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography [J].
Ho, KYJAM ;
Leiner, T ;
de Haan, MW ;
Kessels, AGH ;
Kitslaar, PJEHM ;
van Engelshoven, JMA .
RADIOLOGY, 1998, 206 (03) :683-692