Capacitively coupled contactless conductivity detection in capillary electrophoresis

被引:176
作者
Zemann, AJ [1 ]
机构
[1] Univ Innsbruck, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
关键词
anion; capacitively coupled contactless conductivity detection; capillary electrophoresis; cation; review;
D O I
10.1002/elps.200305476
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capacitively coupled contactless conductivity detection (C(4)D) has become an accepted detection method in capillary electrophoresis (CE) for a variety of analytes. Advantages of this technique over optical detection modes and galvanic contact conductivity detection include great flexibility in capillary handling and rather simple mechanical parts and electronics, as it can be performed in an on-capillary mode. Furthermore, the detection principle can be used with capillaries made of other materials than fused silica (PEEK(R), Teflon(R)), with chip-based separation technologies, or with capillaries having very small inner diameters. This review presents a discussion of the published literature on C(4)D for CE and capillary electrochromatography.
引用
收藏
页码:2125 / 2137
页数:13
相关论文
共 80 条
  • [1] QUANTITATIVE-ANALYSIS IN CAPILLARY ZONE ELECTROPHORESIS WITH CONDUCTIVITY AND INDIRECT UV DETECTION
    ACKERMANS, MT
    EVERAERTS, FM
    BECKERS, JL
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 549 (1-2): : 345 - 355
  • [2] DETERMINATION OF CATIONS AND ANIONS BY CAPILLARY ELECTROPHORESIS COMBINED WITH SUPPRESSED CONDUCTIVITY DETECTION
    AVDALOVIC, N
    POHL, CA
    ROCKLIN, RD
    STILLIAN, JR
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (10) : 1470 - 1475
  • [3] Baltussen E, 2002, ELECTROPHORESIS, V23, P2888, DOI 10.1002/1522-2683(200209)23:17<2888::AID-ELPS2888>3.0.CO
  • [4] 2-4
  • [5] Electronic protection methods for conductivity detectors in micro capillary electrophoresis devices
    Bastemeijer, J
    Lubking, W
    Laugere, F
    Vellekoop, M
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 83 (1-3) : 98 - 103
  • [6] Ampholytes as background electrolytes in capillary zone electrophoresis: Sense or nonsense? Histidine as a model ampholyte
    Beckers, JL
    [J]. ELECTROPHORESIS, 2003, 24 (03) : 548 - 556
  • [7] Berthold A, 2002, ELECTROPHORESIS, V23, P3511, DOI 10.1002/1522-2683(200210)23:20<3511::AID-ELPS3511>3.0.CO
  • [8] 2-C
  • [9] Dual photometric-contactless conductometric detector for capillary electrophoresis
    Chvojka, T
    Jelínek, I
    Opekar, F
    Stulík, K
    [J]. ANALYTICA CHIMICA ACTA, 2001, 433 (01) : 13 - 21
  • [10] Separation of twenty underivatized essential amino acids by capillary zone electrophoresis with contactless conductivity detection
    Coufal, P
    Zuska, J
    van de Goor, T
    Smith, V
    Gas, B
    [J]. ELECTROPHORESIS, 2003, 24 (04) : 671 - 677