Biomechanics of a Lumbar Interspinous Anchor with Transforaminal Lumbar Interbody Fixation

被引:31
作者
Kaibara, Taro [1 ]
Karahalios, Dean G. [2 ,3 ]
Porter, Randall W. [1 ]
Kakarla, Udaya K. [1 ]
Reyes, Phillip M. [1 ]
Choi, Seok Kwang [1 ]
Yaqoobi, Ali S. [1 ]
Crawford, Neil R. [1 ]
机构
[1] Barrow Neurol Inst, Phoenix, AZ 85013 USA
[2] Chicago Inst Neurosurg & Neurores, Chicago, IL 60614 USA
[3] Rush Med Coll, Chicago, IL 60612 USA
关键词
Interspinous anchor; Pedicle screw; Transforaminal lumbar interbody fusion; SEGMENTAL SPINAL INSTRUMENTATION; ISTHMIC SPONDYLOLISTHESIS; INVITED SUBMISSION; INTERNAL-FIXATION; PERIPHERAL-NERVES; SCREW FIXATION; PEDICLE SCREW; FUSION; PLATE; DISORDERS;
D O I
10.1016/j.wneu.2010.02.025
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
OBJECT: To study the stability offered by a clamping lumbar interspinous anchor (ISA) for transforaminal lumbar interbody fusion (TLIF). METHODS: Seven human cadaveric lumbosacral specimens were tested: 1) intact; 2) after placing ISA; 3) after TLIF with ISA; 4) with TLIF, ISA, and unilateral pedicle screws-rod; 5) with TLIF and unilateral pedicle screws-rod (ISA removed); and 6) with TLIF and bilateral pedicle screws-rods. Pure moments (7.5 Nm maximum) were applied in each plane to induce flexion-extension, axial rotation, and lateral bending while recording angular motion optoelectronically. Compression (400 N) was applied while upright foraminal height was measured. RESULTS: All instrumentation reduced angular range of motion (ROM) significantly from normal. The loading modes in which the ISA limited ROM most effectively were flexion and extension, where the ROM allowed was equivalent to that of pedicle screws-rods (P > .08). The ISA was least effective in reducing lateral bending, with this mode reduced to 81% of normal. TLIF with unilateral pedicle screws-rod was the least stable configuration. Addition of the ISA to this construct significantly improved stability during flexion, extension, lateral bending, and axial rotation (P < .008). Constructs that included the ISA increased the foraminal height an average of 0.7 mm more than the other constructs (P < .05). CONCLUSIONS: In cadaveric testing, the ISA limits flexion and extension equivalently to pedicle screws-rods. It also increases foraminal height. When used with TLIF, a construct of ISA or ISA plus unilateral pedicle screws-rod may offer an alternative to bilateral pedicle screws-rods for supplemental posterior fixation.
引用
收藏
页码:572 / 577
页数:6
相关论文
共 30 条
[1]
Beringer Will F, 2006, Neurosurg Focus, V20, pE4
[2]
POSTERIOR SPINAL-FUSION USING INTERNAL-FIXATION WITH THE DAAB PLATE [J].
BOSTMAN, O ;
MYLLYNEN, P ;
RISKA, EB .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (03) :310-314
[3]
COBEY MC, 1971, CLIN ORTHOP RELAT R, P138
[4]
A new technique for determining 3-D joint angles: the tilt/twist method [J].
Crawford, NR ;
Yamaguchi, GT ;
Dickman, CA .
CLINICAL BIOMECHANICS, 1999, 14 (03) :153-165
[5]
AN APPARATUS FOR APPLYING PURE NONCONSTRAINING MOMENTS TO SPINE SEGMENTS IN-VITRO [J].
CRAWFORD, NR ;
BRANTLEY, AGU ;
DICKMAN, CA ;
KOENEMAN, EJ .
SPINE, 1995, 20 (19) :2097-2100
[6]
Construction of local vertebral coordinate systems using a digitizing probe - Technical note [J].
Crawford, NR ;
Dickman, CA .
SPINE, 1997, 22 (05) :559-563
[7]
Crawford NR, 1998, J SPINAL DISORD, V11, P416
[8]
Biomechanical comparison of spondylolysis fixation techniques [J].
Deguchi, M ;
Rapoff, AJ ;
Zdeblick, TA .
SPINE, 1999, 24 (04) :328-333
[9]
TRANSPEDICULAR SCREW-ROD FIXATION OF THE LUMBAR SPINE - OPERATIVE TECHNIQUE AND OUTCOME IN 104 CASES [J].
DICKMAN, CA ;
FESSLER, RG ;
MACMILLAN, M ;
HAID, RW .
JOURNAL OF NEUROSURGERY, 1992, 77 (06) :860-870
[10]
INTERSPINOUS PROCESS SEGMENTAL SPINAL INSTRUMENTATION [J].
DRUMMOND, D ;
GUADAGNI, J ;
KEENE, JS ;
BREED, A ;
NARECHANIA, R .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1984, 4 (04) :397-404