Chemically modified, immobilized trypsin reactor with improved digestion efficiency

被引:69
作者
Freije, JR [1 ]
Mulder, PPMFA [1 ]
Werkman, W [1 ]
Rieux, L [1 ]
Niederlander, HAG [1 ]
Verpoorte, E [1 ]
Bischoff, R [1 ]
机构
[1] Univ Groningen, Ctr Pharm, NL-9713 AV Groningen, Netherlands
关键词
immobilized trypsin; digestion reactors; chemical modification; acetylation; proteomics;
D O I
10.1021/pr050142y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Tryptic digestion followed by identification using mass spectrometry is an important step in many proteomic studies. Here, we describe the preparation of immobilized, acetylated trypsin for enhanced digestion efficacy in integrated protein analysis platforms. Complete digestion of cytochrome c was obtained with two types of modified-trypsin beads with a contact time of only 4 s, while corresponding unmodified-trypsin beads gave only incomplete digestion. The digestion rate of myoglobin, a protein known to be rather resistant to proteolysis, was not altered by acetylating trypsin and required a buffer containing 35% acetonitrile to obtain complete digestion. The use of acetylated-trypsin beads led to fewer interfering tryptic autolysis products, indicating an increased stability of this modified enzyme. Importantly, the modification did not affect trypsin's substrate specificity, as the peptide map of myoglobin was not altered upon acetylation of immobilized trypsin. Kinetic digestion experiments in solution with low-molecular-weight substrates and cytochrome c confirmed the increased catalytic efficiency (lower K-M and higher k(cat)) and increased resistance to autolysis of trypsin upon acetylation. Enhancement of catalytic efficiency was correlated with the number of acetylations per molecule. The favorable properties of the new chemically modified trypsin reactor should make it a valuable tool in automated protein analysis systems.
引用
收藏
页码:1805 / 1813
页数:9
相关论文
共 52 条
[11]   Stabilization of trypsin by chemical modification with β-cyclodextrin monoaldehyde [J].
Fernández, M ;
Fragoso, A ;
Cao, R ;
Baños, M ;
Villalonga, ML ;
Villalonga, R .
BIOTECHNOLOGY LETTERS, 2002, 24 (17) :1455-1459
[12]  
FREIJE JR, 2005, Patent No. 05051866
[13]   Integrated microfluidic system enabling protein digestion, peptide separation, and protein identification [J].
Gao, J ;
Xu, JD ;
Locascio, LE ;
Lee, CS .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2648-2655
[14]   IDENTIFYING PROTEINS FROM 2-DIMENSIONAL GELS BY MOLECULAR MASS SEARCHING OF PEPTIDE-FRAGMENTS IN PROTEIN-SEQUENCE DATABASES [J].
HENZEL, WJ ;
BILLECI, TM ;
STULTS, JT ;
WONG, SC ;
GRIMLEY, C ;
WATANABE, C .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (11) :5011-5015
[15]   Automated analytical system for the examination of protein primary structure [J].
Hsieh, YLF ;
Wang, HQ ;
Elicone, C ;
Mark, J ;
Martin, SA ;
Regnier, F .
ANALYTICAL CHEMISTRY, 1996, 68 (03) :455-462
[16]  
Hunyadi-Gulyas E., 2004, DRUG DISCOV TODAY, V3, pS3
[17]   PROTEIN IDENTIFICATION BY MASS PROFILE FINGERPRINTING [J].
JAMES, P ;
QUADRONI, M ;
CARAFOLI, E ;
GONNET, G .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1993, 195 (01) :58-64
[18]   Artifacts and unassigned masses encountered in peptide mass mapping [J].
Karty, JA ;
Ireland, MME ;
Brun, YV ;
Reilly, JP .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 782 (1-2) :363-383
[19]   Monolithic bioreactor immobilizing trypsin for high-throughput analysis [J].
Kato, M ;
Inuzuka, K ;
Sakai-Kato, K ;
Toyo'oka, T .
ANALYTICAL CHEMISTRY, 2005, 77 (06) :1813-1818
[20]  
Keil B., 1992, SPECIFICITY PROTEOLY, DOI [10.1007/978-3-642-48380-6, DOI 10.1007/978-3-642-48380-6]