Automated metabolic gas analysis systems - A review

被引:136
作者
Macfarlane, DJ [1 ]
机构
[1] Univ Hong Kong, Phys Educ & Sports Sci Unit, Hong Kong, Hong Kong, Peoples R China
关键词
D O I
10.2165/00007256-200131120-00002
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The use of automated metabolic gas analysis systems or metabolic measurement carts (MMC) in exercise studies is common throughout the industrialised world. They have become essential tools for diagnosing many hospital patients, especially those with cardiorespiratory disease. Moreover, the measurement of maximal oxygen uptake ((V) over dot O-2max) is routine for many athletes in fitness laboratories and has become a defacto standard in spite of its limitations. The development of metabolic carts has also facilitated the noninvasive determination of the lactate threshold and cardiac output, respiratory gas exchange kinetics, as well as studies of outdoor activities via small portable systems that often use telemetry. Although the fundamental principles behind the measurement of oxygen uptake ((V) over dot O-2) and carbon dioxide production ((V) over dot CO2) have not changed, the techniques used have, and indeed, some have almost turned through a full circle. Early scientists often employed a manual Douglas bag method together with separate chemical analyses, but the need for faster and more efficient techniques fuelled the development of semi- and full-automated systems by private and commercial institutions. Yet, recently some scientists are returning back to the traditional Douglas bag or Tissot-spirometer methods, or are using less complex automated systems to not only save capital costs, but also to have greater control over the measurement process. Over the last 40 years, a considerable number of automated systems ha ve been developed, with over a dozen commercial manufacturers producing in excess of 20 different automated systems. The validity and reliability of all these different systems is not well known, with relatively few independent studies having been published in this area. For comparative studies to be possible and to facilitate greater consistency of measurements in test-retest or longitudinal studies of individuals, further knowledge about the performance characteristics of these systems is needed. Such information, along with the costs and the common features associated with these systems, may aid physicians and scientists to select a system that is best suited to their requirements and may also improve the quality of these frequently reported physiological measures.
引用
收藏
页码:841 / 861
页数:21
相关论文
共 142 条
[71]  
LLOYD BB, 1958, J PHYSIOL-LONDON, V143, pP5
[72]   THE USE OF LABORATORY TEST-RESULTS WITH LONG-DISTANCE RUNNERS [J].
LONDEREE, BR .
SPORTS MEDICINE, 1986, 3 (03) :201-213
[73]   VALIDITY AND RELIABILITY OF THE COSMED K2 TO MEASURE OXYGEN-UPTAKE [J].
LOTHIAN, F ;
FARRALLY, MR ;
MAHONEY, C .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 1993, 18 (02) :197-206
[74]   COMPARISON OF 3 FIELD METHODS FOR MEASURING OXYGEN-CONSUMPTION [J].
LOUHEVAARA, V ;
ILMARINEN, J ;
OJA, P .
ERGONOMICS, 1985, 28 (02) :463-470
[75]   VALIDITY AND RELIABILITY OF THE COSMED K2 INSTRUMENT [J].
LUCIA, A ;
FLECK, SJ ;
GOTSHALL, RW ;
KEARNEY, JT .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1993, 14 (07) :380-386
[76]  
Macfarlane D., 1991, NZ J SPORTS MED, V19, P13
[77]   MICROPROCESSOR EXERCISE PHYSIOLOGY SYSTEMS VS A NONAUTOMATED SYSTEM - A COMPARISON OF DATA OUTPUT [J].
MATTHEWS, JI ;
BUSH, BA ;
MORALES, FM .
CHEST, 1987, 92 (04) :696-703
[78]  
MCARDLE WD, 1973, MED SCI SPORT EXER, V5, P156
[79]   Validation of the COSMED K4 b2 portable metabolic system [J].
McLaughlin, JE ;
King, GA ;
Howley, ET ;
Bassett, DR ;
Ainsworth, BE .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2001, 22 (04) :280-284
[80]  
MCLAUGHLIN JE, 1999, MED SCI SPORTS EX S5, V31, pS285