Comparative study of [three] LC-MALDI workflows for the analysis of complex proteomic samples

被引:30
作者
Hattan, SJ
Marchese, J
Khainovski, N
Martin, S
Juhasz, P
机构
[1] Appl Biosyst Inc, Framingham, MA 01701 USA
[2] BG Med, Waltham, MA 02451 USA
关键词
yeast; two dimensional chromatography; LC-MALDI; MALDI; workflow; proteomics; shotgun proteomics;
D O I
10.1021/pr050099e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Large-scale proteomic analyses frequently rely on high-resolution peptide separation of digested protein mixtures in multiple dimensions to achieve accuracy in sample detection and sensitivity in dynamic range of coverage. This study was undertaken to demonstrate the feasibility of MALDI MS/MS with off-line coupling to HPLC for the analysis of whole cell lysates of wild-type yeast by three different workflows: SCX-RPHPLC-MS/MS, high-pH SAX-RPHPLC-MS/MS and RP (protein)-SCX-RPHPLC-MS/MS. The purpose of these experiments was to demonstrate the effect of a workflow on the end results in terms of the number of proteins detected, the average peptide coverage of proteins, and the number of redundant peptide sequencing attempts. Using 60 mu g of yeast lysate, minor differences were seen in the number of proteins detected by each method (800-1200). The most significant differences were observed in redundancy of MS/MS acquisitions.
引用
收藏
页码:1931 / 1941
页数:11
相关论文
共 59 条
[21]  
2-X
[22]  
Juhasz P, 2002, MASS SPECTROMETRY AND HYPHENATED TECHNIQUES IN NEUROPEPTIDE RESEARCH, P375
[23]   Automatic identification of proteins with a MALDI-quadrupole ion trap mass spectrometer [J].
Krutchinsky, AN ;
Kalkum, M ;
Chait, BT .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5066-5077
[24]  
Langen H, 2000, ELECTROPHORESIS, V21, P411, DOI 10.1002/(SICI)1522-2683(20000101)21:2<411::AID-ELPS411>3.0.CO
[25]  
2-4
[26]   Identification of 2D-gel proteins:: A comparison of MALDI/TOF peptide mass mapping to μ LC-ESI tandem mass spectrometry [J].
Lim, H ;
Eng, J ;
Yates, JR ;
Tollaksen, SL ;
Giometti, CS ;
Holden, JF ;
Adams, MWW ;
Reich, CI ;
Olsen, GJ ;
Hays, LG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (09) :957-970
[27]   Direct analysis of protein complexes using mass spectrometry [J].
Link, AJ ;
Eng, J ;
Schieltz, DM ;
Carmack, E ;
Mize, GJ ;
Morris, DR ;
Garvik, BM ;
Yates, JR .
NATURE BIOTECHNOLOGY, 1999, 17 (07) :676-682
[28]  
Loboda AV, 2000, RAPID COMMUN MASS SP, V14, P1047, DOI 10.1002/1097-0231(20000630)14:12<1047::AID-RCM990>3.0.CO
[29]  
2-E
[30]   Characterization of poly(butylene terephthalate) by size-exclusion chromatography and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Lou, XW ;
van Dongen, JLJ ;
Janssen, HM ;
Lange, RFM .
JOURNAL OF CHROMATOGRAPHY A, 2002, 976 (1-2) :145-154