Accuracy of Cardiac Magnetic Resonance of Absolute Myocardial Blood Flow With a High-Field System Comparison With Conventional Field Strength

被引:18
作者
Christian, Timothy F. [1 ]
Bell, Stephen P. [1 ]
Whitesell, Lawrence [2 ]
Jerosch-Herold, Michael [3 ]
机构
[1] Univ Vermont, Coll Med, Burlington, VT 05495 USA
[2] Univ Wisconsin, Coll Med, Madison, WI USA
[3] Harvard Univ, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
cardiac imaging; CMR; coronary flow reserve; ischemia; myocardial perfusion; STATE FREE PRECESSION; PERFUSION; MR; CONTRAST; 3-TESLA; TISSUE; SATURATION; TRANSIT; HEART; TESLA;
D O I
10.1016/j.jcmg.2009.06.009
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
OBJECTIVES The aim of this study was to determine the accuracy of cardiac magnetic resonance (CMR) first pass (FP) perfusion measures of absolute myocardial blood flow (MBF) with a 3.0-T magnet and compare these measures with FP perfusion at 1.5-T with absolute MBF by labeled microspheres as the gold standard. BACKGROUND First-pass magnetic resonance (MR) myocardial perfusion imaging can quantify MBF, but images are of low signal at conventional magnetic field strength due to the need for rapid acquisition. METHODS A pig model was used to alter MBF in a coronary artery during FP CMR (intracoronary adenosine followed by ischemia). This produces an active zone with a range of MBF and a control zone. Microspheres were injected into the left atrium with concurrent reference sampling. FP MR perfusion imaging was performed at 1.5-T (n = 9) or 3.0-T (n = 8) with a saturation-recovery gradient echo sequence in short-axis slices during a bolus injection of 0.025 mmol/kg gadolinium-diethylenetriamine pentaacetic acid. Fermi function deconvolution was performed on active and control region of interest from short-axis slices with an arterial input function derived from the left ventricular cavity. These MR values of MBF were matched to microsphere values obtained from short-axis slices at pathology. RESULTS Occlusion MBF was 0.21 +/- 0.26 ml/min/g, adenosine MBF was 2.28 +/- 0.99 ml/min/g, and control zone MBF was 0.70 +/- 0.22 ml/min/g. The correlation of MR FP CMR with microsphere was close for both field strengths: 3.0-T, r = 0.98, p < 0.0001 and 1.5-T, r = 0.95, p < 0.0001. The 95% confidence limits of agreement were slightly narrower at 3.0-T (3.0-T = 0.49 ml/min/g, 1.5-T = 0.68 ml/min/g, p < 0.05). The FP CMR image characteristics were better at 3.0-T (noise and contrast enhancement were both superior at 3.0-T). In myocardial zones where MBF <0.50 ml/min/g, the correlation with microspheres was closer at 3.0-T (r = 0.55 at 1.5-T, r = 0.85 at 3.0-T). CONCLUSIONS Absolute MBF by FP perfusion imaging is accurate at both 1.5- and 3.0-T. Signal quality is better at 3.0-T, which might confer a benefit for estimating MBF in ischemic zones. (J Am Coll Cardiol Img 2009;2:1103-10) (C) 2009 by the American College of Cardiology Foundation
引用
收藏
页码:1103 / 1110
页数:8
相关论文
共 31 条
[1]
3 Tesla MR imaging provides improved contrast in first-pass myocardial perfusion imaging over a range of gadolinium doses [J].
Araoz, PA ;
Glockner, JF ;
Mcgee, KP ;
Potter, DD ;
Valeti, VU ;
Stanley, DW ;
Christian, TF .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (03) :559-564
[2]
TISSUE MEAN TRANSIT-TIME FROM DYNAMIC COMPUTED-TOMOGRAPHY BY A SIMPLE DECONVOLUTION TECHNIQUE [J].
AXEL, L .
INVESTIGATIVE RADIOLOGY, 1983, 18 (01) :94-99
[3]
Bassingthwaighte JB., 1984, Handbook of Physiology, P549
[4]
Tissue warming and regulatory responses induced by radio frequency energy deposition on a whole-body 3-tesla magnetic resonance imager [J].
Boss, Andreas ;
Graf, Hansjoerg ;
Berger, Alexander ;
Lauer, Ulrike A. ;
Wojtczyk, Hanne ;
Claussen, Claus D. ;
Schick, Fritz .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (05) :1334-1339
[5]
Cardiovascular magnetic resonance perfusion imaging at 3-Tesla for the detection of coronary artery disease - A comparison with 1.5-Tesla [J].
Cheng, Adrian S. H. ;
Pegg, Tammy J. ;
Karamitsos, Theodoros D. ;
Searle, Nick ;
Jerosch-Herold, Michael ;
Choudhury, Robin P. ;
Adrian, P. Banning ;
Neubauer, Stefan ;
Robson, Matthew D. ;
Selvanayagam, Joseph B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (25) :2440-2449
[6]
Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging [J].
Christian, TF ;
Rettmann, DW ;
Aletras, AH ;
Liao, SL ;
Taylor, JL ;
Balaban, RS ;
Arai, AE .
RADIOLOGY, 2004, 232 (03) :677-684
[7]
Anatomy of an emerging diagnostic test - Computed tomographic coronary angiography [J].
Christian, TF .
CIRCULATION, 2005, 112 (15) :2222-2225
[8]
Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: Comparison to single-bolus injection method [J].
Christian, Timothy F. ;
Aletras, Anthony H. ;
Arai, Andrew E. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) :1271-1277
[9]
Diagnostic performance of myocardial perfusion MR at 3 T in patients with coronary artery disease [J].
Gebker, Rolf ;
Jahnke, Cosima ;
Paetsch, Ingo ;
Kelle, Sebastian ;
Schnackenburg, Bernhard ;
Fleck, Eckart ;
Nagel, Eike .
RADIOLOGY, 2008, 247 (01) :57-63
[10]
Comprehensive cardiac magnetic resonance imaging at 3.0 tesla - Feasibility and implications for clinical applications [J].
Gutberlet, M ;
Noeske, R ;
Schwinge, K ;
Freyhardt, P ;
Felix, R ;
Niendorf, T .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :154-167