Pre-concentration system for bismuth determination in urine using FI-ICP-AES with ultrasonic nebulization

被引:50
作者
Moyano, S [1 ]
Gásquez, JA [1 ]
Olsina, R [1 ]
Marchevsky, E [1 ]
Martinez, LD [1 ]
机构
[1] Univ Nacl San Luis Chacabuco & Pedernera, Fac Quim Bioquim & Farm, Area Quim Analit, RA-5700 San Luis, Argentina
关键词
D O I
10.1039/a807588c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A bismuth pre-concentration and determination system implemented with inductively coupled plasma atomic emission spectrometry( ICP-AES) associated with a flow-injection (FI) method with an ultrasonic nebulizalion system was studied. For the retention and on-line pre-concentration of bismuth, quinolin-8-ol and Amberlite XAD-7 were used at pH 5.0. The bismuth complex was removed from the micro-column with nitric acid. The detection limit for the pre-concentration of 100 ml of aqueous solution was 0.03 ng ml(-1) with a relative standard deviation (RSD), of 2.5%, calculated with the peak heights obtained. The RSD for the human urine samples were between 1 and 5%. This reflects the cumulative imprecision of all the process. The calibration graph using the preconcentration system for bismuth was linear with a correlation coefficient of 0.9991 at levels near the detection limits up to at least 100 ng ml(-1). The method was succesfully applied to the determination of bismuth in human urine samples digested previously with a mixture of H2O2 and HNO3.
引用
收藏
页码:259 / 262
页数:4
相关论文
共 34 条
[1]   Sorption of arsenic, bismuth, mercury, antimony, selenium and tin on dithiocarbamate loaded polyurethane foam as a preconcentration method for their determination in water samples by simultaneous inductively coupled plasma atomic emission spectrometry and electrothermal atomic absorption spectrometry [J].
Arpadjan, S ;
Vuchkova, L ;
Kostadinova, E .
ANALYST, 1997, 122 (03) :243-246
[2]  
BALDELLI M, 1994, ANALUSIS, V22, P147
[3]   PRECONCENTRATION AND SEPARATION OF METAL-IONS BY MEANS OF AMBERLITE XAD-2 LOADED WITH PYROCATECHOL VIOLET [J].
BRAJTER, K ;
OLBRYCHSLESZYNSKA, E ;
STASKIEWICZ, M .
TALANTA, 1988, 35 (01) :65-67
[4]   Determination of bismuth in urine and prescription medicines using atomic absorption with an on-line hydride generation system [J].
Cadore, S ;
dos Anjos, AP ;
Baccan, N .
ANALYST, 1998, 123 (08) :1717-1719
[5]   THE ASSESSMENT OF REFERENCE VALUES FOR ELEMENTS IN HUMAN BIOLOGICAL TISSUES AND FLUIDS - A SYSTEMATIC REVIEW [J].
CAROLI, S ;
ALIMONTI, A ;
CONI, E ;
PETRUCCI, F ;
SENOFONTE, O ;
VIOLANTE, N .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1994, 24 (5-6) :363-398
[6]   Properties and applications of polyacrylacylisothiourea chelating fiber for preconcentration and separation of trace titanium, vanadium and bismuth [J].
Chang, XJ ;
Su, ZX ;
Li, YF ;
Zhan, GY ;
Luo, XY .
MIKROCHIMICA ACTA, 1997, 126 (1-2) :137-140
[7]  
Chang XJ, 1996, ANAL LETT, V29, P1861
[8]   SYNTHESIS AND ANALYTICAL CHARACTERIZATION OF A CHELATING RESIN LOADED WITH DITHIZONE [J].
CHWASTOWSKA, J ;
KOSIARSKA, E .
TALANTA, 1988, 35 (06) :439-442
[9]   ONLINE ION-EXCHANGE SEPARATION AND DETERMINATION OF NIOBIUM, TANTALUM, TUNGSTEN, ZIRCONIUM AND HAFNIUM IN HIGH-PURITY IRON BY FLOW-INJECTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
COEDO, AG ;
LOPEZ, TD ;
ALGUACIL, F .
ANALYTICA CHIMICA ACTA, 1995, 315 (03) :331-338
[10]  
Fairman B, 1996, FRESEN J ANAL CHEM, V355, P757