Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose
被引:21
作者:
论文数: 引用数:
h-index:
机构:
Cho, Eun-Suk
[1
]
Chung, Tae-Sub
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Gangnam Severance Hosp, Dept Radiol, Coll Med, Seoul 135720, South KoreaYonsei Univ, Gangnam Severance Hosp, Dept Radiol, Coll Med, Seoul 135720, South Korea
Chung, Tae-Sub
[1
]
论文数: 引用数:
h-index:
机构:
Ahn, Sung Jun
[2
]
Chong, KyoungHoon
论文数: 0引用数: 0
h-index: 0
机构:
Siemens Healthcare Korea, Seoul 120837, South KoreaYonsei Univ, Gangnam Severance Hosp, Dept Radiol, Coll Med, Seoul 135720, South Korea
Chong, KyoungHoon
[3
]
Baek, Jang Hun
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Gangnam Severance Hosp, Dept Radiol, Coll Med, Seoul 135720, South KoreaYonsei Univ, Gangnam Severance Hosp, Dept Radiol, Coll Med, Seoul 135720, South Korea
Baek, Jang Hun
[1
]
Suh, Sang Hyun
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Gangnam Severance Hosp, Dept Radiol, Coll Med, Seoul 135720, South KoreaYonsei Univ, Gangnam Severance Hosp, Dept Radiol, Coll Med, Seoul 135720, South Korea
Suh, Sang Hyun
[1
]
机构:
[1] Yonsei Univ, Gangnam Severance Hosp, Dept Radiol, Coll Med, Seoul 135720, South Korea
[2] Yonsei Univ, Gangnam Severance Hosp, Dept Radiol, Coll Med, Seoul 120752, South Korea
[3] Siemens Healthcare Korea, Seoul 120837, South Korea
To determine the feasibility of using a 70-kVp protocol compared with a 120-kVp protocol for cerebral CT angiography. An additional target was to investigate a possible reduction in the volume of contrast medium (CM) using the 70-kVp protocol. Attenuation value and CNR for iodine were determined at various tube voltage settings using a phantom. Sixty-nine volunteers were randomly assigned to one of three protocols: group A (120-kVp and CM 64 mL), group B (70-kVp and CM 64 mL), or group C (70-kVp and CM 40 mL). The attenuation value, SNR, and CNR of cerebral arteries, subjective image quality, and radiation dose were compared among the groups. The vascular attenuation, SNR, and CNR of group B were significantly higher than those of group A. Group C had a significantly higher vascular attenuation than group A. Groups B and C were significantly better than group A with respect to subjective image quality. An effective dose of 70-kVp was 10 % lower than that of 120-kVp. Using 70-kVp improved arterial enhancement, SNR, and CNR, and provided better subjective image quality, using a 10 % lower effective dose. Furthermore, the 70-kVp protocol may both reduce volume of CM by 37.5 % and improve arterial enhancement. aEuro cent Cerebral CT angiography at 70-kVp substantially improved vascular enhancement aEuro cent Subjective image quality was better at 70-kVp, with lower radiation dose aEuro cent The volume of contrast media can be substantially reduced at 70-kVp.
机构:
Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea
Chung, Tae-Sub
;
Oh, Dae Kun
论文数: 0引用数: 0
h-index: 0
机构:
Armed Forces Capital Hosp Korea, Dept Radiol, Songnam, Gyeonggi Do, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea
Oh, Dae Kun
;
Choi, Hyun Seok
论文数: 0引用数: 0
h-index: 0
机构:
Catholic Univ, Coll Med, Seoul St Marys Hosp, Dept Radiol, Seoul, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea
Choi, Hyun Seok
;
Suh, Sang Hyun
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea
Suh, Sang Hyun
;
Lee, Hyeon-Kyeong
论文数: 0引用数: 0
h-index: 0
机构:
Armed Forces Capital Hosp Korea, Dept Radiol, Songnam, Gyeonggi Do, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea
Lee, Hyeon-Kyeong
;
Lee, Kyung Hee
论文数: 0引用数: 0
h-index: 0
机构:
Armed Forces Capital Hosp Korea, Dept Radiol, Songnam, Gyeonggi Do, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea
机构:
Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea
Chung, Tae-Sub
;
Oh, Dae Kun
论文数: 0引用数: 0
h-index: 0
机构:
Armed Forces Capital Hosp Korea, Dept Radiol, Songnam, Gyeonggi Do, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea
Oh, Dae Kun
;
Choi, Hyun Seok
论文数: 0引用数: 0
h-index: 0
机构:
Catholic Univ, Coll Med, Seoul St Marys Hosp, Dept Radiol, Seoul, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea
Choi, Hyun Seok
;
Suh, Sang Hyun
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea
Suh, Sang Hyun
;
Lee, Hyeon-Kyeong
论文数: 0引用数: 0
h-index: 0
机构:
Armed Forces Capital Hosp Korea, Dept Radiol, Songnam, Gyeonggi Do, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea
Lee, Hyeon-Kyeong
;
Lee, Kyung Hee
论文数: 0引用数: 0
h-index: 0
机构:
Armed Forces Capital Hosp Korea, Dept Radiol, Songnam, Gyeonggi Do, South KoreaYonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 135720, South Korea