Contrast-enhanced magnetic resonance angiography of the carotid arteries:: Influence of injection rates and volumes on arterial-venous transit time

被引:12
作者
Herold, T [1 ]
Paetzel, C [1 ]
Völk, M [1 ]
Bachthaler, M [1 ]
Zorger, N [1 ]
Feuerbach, S [1 ]
Strotzer, M [1 ]
Lenhart, M [1 ]
机构
[1] Univ Hosp Regensburg, Dept Diagnost Radiol, D-93042 Regensburg, Germany
关键词
carotid arteries; magnetic resonance; magnetic resonance angiography;
D O I
10.1097/01.rli.0000105040.40925.c8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evaluated. Materials and Methods: In 60 patients a CM injection was necessary to investigate suspected cranial disease. All patients were prospectively assigned to 6 protocol groups with varying volumes of gadolinium dimeglumine (2, 10, 20 mL) and injection rates (0.5, 1, 2, 4 mL/s). Simultaneously to the CM injection, 50 repetitive transverse measurements (l/s) were acquired at the level of the common carotid artery. Based on the resulting signal-time curves, the arrival time of the contrast material in the common carotid artery and the jugular vein, the resulting arterial-venous transit time, the peak enhancement and the extent of a CM-plateau were calculated as a function of the injection parameters. Results: Smaller flow rates (0.5 mL/s) resulted in a longer arrival time in the common carotid artery (mean value 22,6 seconds +/- 2.3) and the jugular vein (mean value 32.6 seconds +/- 2.6) and resulted in longer arterial-venous transit time (mean value 10.1 second +/- 1.9). The volume showed no effect on these parameters. The peak arterial and venous signal intensity and a consistent CM-plateau after 50 seconds were dependent on the volume, but not on the injection rate. Conclusion: The injection rate showed an influence to the arrival time in the common carotid artery and the jugular vein and also to the arterial-venous transit time. The injected volume only affected the extent of the contrast plateau. A flow rate of 1 to 2 mL/s and a minimum of 20 mL, gadolinium dimeglumine are recommended to achieve optimal image quality without venous overlay.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 30 条
[1]   Arterial first pass gadolinium-CM dynamics as a function of several intravenous saline flush and Gd volumes [J].
Boos, M ;
Scheffler, K ;
Haselhorst, R ;
Reese, E ;
Fröhlich, J ;
Bongartz, GM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :568-576
[2]   The effect of injection rate on time-resolved contrast-enhanced peripheral MRA [J].
Carroll, TJ ;
Korosec, FR ;
Swan, JS ;
Hany, TF ;
Grist, TM ;
Mistretta, CA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) :401-410
[3]   Carotid bifurcation: Evaluation of time-resolved three-dimensional contrast-enhanced MR angiography [J].
Carroll, TJ ;
Korosec, FR ;
Petermann, GM ;
Grist, TM ;
Turski, PA .
RADIOLOGY, 2001, 220 (02) :525-532
[4]   3D gadolinium-enhanced MR angiography of the carotid arteries [J].
Cloft, HJ ;
Murphy, KJ ;
Prince, MR ;
Brunberg, JA .
MAGNETIC RESONANCE IMAGING, 1996, 14 (06) :593-600
[5]   Fluoroscopically triggered contrast-enhanced 3D MR DSA and 3D time-of-flight turbo MRA of the carotid arteries: first clinical experiences in correlation with ultrasound, x-ray angiography, and endarterectomy findings [J].
Fellner, FA ;
Fellner, C ;
Wutke, R ;
Lang, W ;
Laub, G ;
Schmidt, M ;
Janka, R ;
Denzel, C ;
Bautz, W .
MAGNETIC RESONANCE IMAGING, 2000, 18 (05) :575-585
[6]   Optimization of contrast timing for breath-hold three-dimensional MR angiography [J].
Hany, TF ;
McKinnon, GC ;
Leung, DA ;
Pfammatter, T ;
Debatin, JF .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :551-556
[7]   Peripheral vascular tree stenoses: Detection with subtracted and nonsubtracted MR angiography [J].
Ho, KYJAM ;
de Haan, MW ;
Kessels, AGH ;
Kitslaar, PJEHM ;
van Engelshoven, JMA .
RADIOLOGY, 1998, 206 (03) :673-681
[8]  
HUESLER J, 2001, STAT PRINCIPLES MED
[9]  
Huston J, 2001, RADIOLOGY, V218, P138
[10]   Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography [J].
Kim, JK ;
Farb, RI ;
Wright, GA .
RADIOLOGY, 1998, 206 (01) :283-289