Stripping voltammetric determination of mercury(II) at antimony-coated carbon paste electrode

被引:59
作者
Ashrafi, Amir M. [1 ]
Vytras, Karel [1 ]
机构
[1] Univ Pardubice, Dept Analyt Chem, CZ-53210 Pardubice, Czech Republic
关键词
Antimony film electrodes; Carbon paste electrodes; Stripping voltammetry; Mercury(II) determination; Cadmium(II) apparent catalytic effect; GOLD DISK ELECTRODE; SEA-WATER; FILM ELECTRODE; AQUATIC CHEMISTRY; TRACES; POLAROGRAPHY; SAMPLES; MARINE; IONS;
D O I
10.1016/j.talanta.2011.07.078
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A new procedure was elaborated to determine mercury(II) using an anodic stripping square-wave voltammetry at the antimony film carbon paste electrode (SbF-CPE). In highly acidic medium of 1 M hydrochloric acid, voltammetric measurements can be realized in a wide potential window. Presence of cadmium(II) allows to separate peaks of Hg(II) and Sb( Ill) and apparently catalyses reoxidation of electrolytically accumulated mercury, thus allowing its determination at ppb levels. Calibration dependence was linear up to 100 ppb Hg with a detection limit of 1.3 ppb. Applicability of the method was tested on the real river water sample. (C) 2011 Published by Elsevier B.V.
引用
收藏
页码:2700 / 2702
页数:3
相关论文
共 42 条
[1]
ARAS NK, 2006, TRACE ELEMENT ANAL F, P252
[2]
Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2000, 424 (01) :65-76
[3]
THE FORMAL POTENTIAL OF THE ANTIMONOUS ANTIMONIC HALF CELL IN HYDROCHLORIC ACID SOLUTIONS [J].
BROWN, RA ;
SWIFT, EH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1949, 71 (08) :2719-2723
[4]
DRASCH GA, 1994, HDB METALS CLIN ANAL, P79
[5]
Determination of mercury in hair by square-wave anodic stripping voltammetry at a rotating gold disk electrode after microwave digestion [J].
East, GA ;
Marinho, EP .
BIOLOGICAL TRACE ELEMENT RESEARCH, 2005, 103 (03) :261-276
[6]
DIRECT DETERMINATION OF MERCURY IN SEA-WATER BY ANODIC-STRIPPING VOLTAMMETRY WITH A GRAPHITE ELECTRODE [J].
FUKAI, R ;
HUYNHNGOC, L .
ANALYTICA CHIMICA ACTA, 1976, 83 (MAY) :375-379
[7]
DETERMINATION OF MERCURY IN FREEZE-DRIED MUSCLE SAMPLES OF PIKE, COD AND PERCH USING AN ASV-TECHNIQUE [J].
GOLIMOWSKI, J ;
GUSTAVSSON, I .
SCIENCE OF THE TOTAL ENVIRONMENT, 1983, 31 (01) :89-98
[8]
ANODIC-STRIPPING SEMI-DIFFERENTIAL ELECTROANALYSIS OF MERCURY(II) AT GOLD DISK ELECTRODE AND ITS APPLICATION TO ENVIRONMENTAL-ANALYSIS [J].
GOTO, M ;
IKENOYA, K ;
ISHII, D .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1980, 53 (12) :3567-3572
[9]
DETERMINATION OF MERCURY IN SEA-WATER BY STRIPPING VOLTAMMETRY [J].
GUSTAVSSON, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 214 (1-2) :31-36
[10]
DETERMINATION OF MERCURY BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY WITH VARIOUS WORKING ELECTRODES - APPLICATION TO THE ANALYSIS OF NATURAL-WATER SEDIMENTS [J].
HATLE, M .
TALANTA, 1987, 34 (12) :1001-1007