Estimated Average Glucose and Self-Monitored Mean Blood Glucose Are Discordant Estimates of Glycemic Control

被引:38
作者
Hempe, James M. [1 ,2 ]
Soros, Arlette A. [1 ]
Chalew, Stuart A. [1 ]
机构
[1] Louisiana State Univ, Hlth Sci Ctr, Dept Pediat, New Orleans, LA USA
[2] Childrens Hosp, Res Inst Child, New Orleans, LA USA
关键词
BIOLOGICAL VARIATION; GLYCATED HEMOGLOBIN; HBA(1C); GLYCOHEMOGLOBIN; VARIABILITY; NEPHROPATHY; A1C;
D O I
10.2337/dc09-1498
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - The A1C-Derived Average Glucose study recommended reporting A1C in estimated average glucose (eAG) equivalents. We compared eAG with self-monitored mean blood glucose (MBG) to determine whether eAG is systematically biased due to biological variation in the relationship between MBG and A1C. RESEARCH DESIGN AND METHODS - MBG and A1C were recorded from charts of 202 pediatric type 1 diabetic patients at 1,612 clinic visits. Patients were divided into groups with low, moderate, or high A1C bias based on a hemoglobin glycation index (HGI). RESULTS - The mean +/- SD values for MBG versus eAG were as follows: total population, 194 +/- 34 vs. 196 +/- 36 mg/dl; low-HGI group, 186 +/- 31 vs. 163 +/- 20 mg/dl; moderate-HGI group, 195 +/- 28 vs. 193 +/- 19 mg/dl; and high-HGI group, 199 +/- 42 vs. 230 +/- 31 mg/dl. CONCLUSIONS - eAG underestimated MBG in low HGI patients and overestimated MBG in high HGI patients. Disagreement between eAG and MBG downloaded from patient glucose meters will cause confusion if eAG is implemented for clinical use.
引用
收藏
页码:1449 / 1451
页数:3
相关论文
共 15 条
[1]   The proposed terminology 'A1c-derived average glucose' is inherently imprecise and should not be adopted [J].
Bloomgarden, Z. T. ;
Inzucchi, S. E. ;
Karnieli, E. ;
Le Roith, D. .
DIABETOLOGIA, 2008, 51 (07) :1111-1114
[2]   Caveats regarding the use of HbA1c for prediction of mean blood glucose [J].
Chalew, S. ;
Hempe, J. M. .
DIABETOLOGIA, 2008, 51 (05) :903-904
[3]   Discordance between HbA1c and fructosamine -: Evidence for a glycosylation gap and its relation to diabetic nephropathy [J].
Cohen, RM ;
Holmes, YR ;
Chenier, TC ;
Joiner, CH .
DIABETES CARE, 2003, 26 (01) :163-167
[4]   Investigation of the mechanism underlying the variability of glycated haemoglobin in non-diabetic subjects not related to glycaemia [J].
Gould, BJ ;
Davie, SJ ;
Yudkin, JS .
CLINICA CHIMICA ACTA, 1997, 260 (01) :49-64
[5]   High and low hemoglobin glycation phenotypes in type 1 diabetes - A challenge for interpretation of glycemic control [J].
Hempe, JM ;
Gomez, R ;
McCarter, RJ ;
Chalew, SA .
JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2002, 16 (05) :313-320
[6]   Variability in the relationship between mean plasma glucose and HbAIc:: Implications for the assessment of glycemic control [J].
Kilpatrick, Eric S. ;
Rigby, Alan S. ;
Atkin, Stephen L. .
CLINICAL CHEMISTRY, 2007, 53 (05) :897-901
[7]   Biological variation of glycated hemoglobin - Implications for diabetes screening and monitoring [J].
Kilpatrick, ES ;
Maylor, PW ;
Keevil, BG .
DIABETES CARE, 1998, 21 (02) :261-264
[8]  
Little RR, 2001, CLIN CHEM, V47, P1985
[9]   Biological variation in HbA1c predicts risk of retinopathy and nephropathy in type 1 diabetes [J].
McCarter, RJ ;
Gomez, R ;
Hempe, JM ;
Chalew, SA .
DIABETES CARE, 2004, 27 (06) :1259-1264
[10]   Fatty acid profile and CLA isomers content of cow, ewe and goat milks processed by high pressure homogenization [J].
Miguel Rodriguez-Alcala, Luis ;
Harte, Federico ;
Fontecha, Javier .
INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2009, 10 (01) :32-36