Screening of ion channel receptor agonists using capillary electrophoresis-patch clamp detection with resensitized detector cells

被引:6
作者
Farre, C
Sjöberg, A
Jardemark, K
Jacobson, I
Orwar, O [1 ]
机构
[1] Univ Gothenburg, Dept Chem, SE-41296 Gothenburg, Sweden
[2] AstraZeneca AB, SE-43183 Molndal, Sweden
关键词
D O I
10.1021/ac001061i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Efficient techniques for identifying endogenous and synthetic ligands of ion channels are important in understanding neuronal communication and for screening drug libraries. This paper describes a technique based on capillary electrophoresis (CE) separation coupled to patch-clamp (PC) detection where a pulsed-flow superfusion scheme was implemented for improved detection. The nicotinic acetylcholine receptor (nAChr) agonists acetylcholine, carbachol, and (-)-nicotine were fractionated and detected by patch-clamped pheochromcytoma detector cells. The high-conductance state of the nAChr during CE-PC detection was maintained aid repetitively resensitized using pulsed-flow superfusion with agonist;fi-ee buffer. In this way, each agonist evoked an ensemble of peak currents that reflected the spatiotemporal distribution for the ligand at the cell surface. The technique takes advantage of the intrinsic high selectivity and sensitivity of membrane-expressed receptors and allowed for resolution and identification of closely migrating ligands. The method was employed for determination of acetylcholine content in cell lysates.
引用
收藏
页码:1228 / 1233
页数:6
相关论文
共 20 条
[1]   GC/olfactometry [J].
Acree, TE .
ANALYTICAL CHEMISTRY, 1997, 69 (05) :A170-A175
[2]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[3]   SIMPLE METHOD FOR MEASURING A PICOGRAM OF ACETYLCHOLINE USING CLAM (MYA-ARENARIA) HEART [J].
COTTRELL, GA ;
POWELL, B ;
STANTON, M .
BRITISH JOURNAL OF PHARMACOLOGY, 1970, 40 (04) :866-&
[4]   Drug screening - Beyond the bottleneck [J].
Dove, A .
NATURE BIOTECHNOLOGY, 1999, 17 (09) :859-863
[5]   Lab-on-a-chip: A revolution in biological and medical sciences. [J].
Figeys, D ;
Pinto, D .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :330A-335A
[6]   IDENTIFICATION OF RECEPTOR LIGANDS AND RECEPTOR SUBTYPES USING ANTAGONISTS IN A CAPILLARY ELECTROPHORESIS SINGLE-CELL BIOSENSOR SEPARATION SYSTEM [J].
FISHMAN, HA ;
ORWAR, O ;
SCHELLER, RH ;
ZARE, RN .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (17) :7877-7881
[7]   ESTABLISHMENT OF A NORADRENERGIC CLONAL LINE OF RAT ADRENAL PHEOCHROMOCYTOMA CELLS WHICH RESPOND TO NERVE GROWTH-FACTOR [J].
GREENE, LA ;
TISCHLER, AS .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1976, 73 (07) :2424-2428
[8]   IMPROVED PATCH-CLAMP TECHNIQUES FOR HIGH-RESOLUTION CURRENT RECORDING FROM CELLS AND CELL-FREE MEMBRANE PATCHES [J].
HAMILL, OP ;
MARTY, A ;
NEHER, E ;
SAKMANN, B ;
SIGWORTH, FJ .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1981, 391 (02) :85-100
[9]   DETERMINATION OF CHOLINE AND ACETYLCHOLINE LEVELS IN RAT-BRAIN REGIONS BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
IKARASHI, Y ;
SASAHARA, T ;
MARUYAMA, Y .
JOURNAL OF CHROMATOGRAPHY, 1985, 322 (01) :191-199
[10]   Screening of receptor antagonists using agonist-activated patch clamp detection in chemical separations [J].
Jardemark, K ;
Farre, C ;
Jacobson, I ;
Zare, RN ;
Orwar, O .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2468-2474