Highly sensitive flow detection of uric acid based on an intermediate regeneration of uricase

被引:23
作者
Hasebe, Y [1 ]
Nawa, K [1 ]
Ujita, S [1 ]
Uchiyama, S [1 ]
机构
[1] Saitama Inst Technol, Fac Engn, Dept Environm Engn, Okabe, Saitama 3690293, Japan
关键词
enzymatic methods; flow injection; uric acid; immobilized uricase; signal amplification; intermediate regeneration; dithiothreitol;
D O I
10.1039/a802214c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The principle of the signal amplification of a uric acid sensor based on dithiothreitol (DTT)-mediated intermediate regeneration of uricase was applied to a flow-injection system with an immobilized uricase reactor and a DTT-containing carrier. Highly sensitive detection for nM to mu M Order of uric acid was achieved when 10 mM TRIS-HCl buffer (pH 10.0) containing 20 mM DTT was used as a carrier at 0.6 ml min(-1) and 37 degrees C, The sensitivity of the uric acid was much improved over a batch method using a uricase membrane-coupling electrode, and the detection limit (ca, peak current 8 nA) of uric acid was found to be down to 3 x 10(-10) M (amplification factor; more than 10 000), This chemically amplified flow-system is very useful for the direct assay of uric acid in highly diluted biological fluids (urine and serum) without complicated pretreatment of the samples, because this sensor has the potential to detect trace amounts (nM to FCM) Of uric acid in highly diluted body fluids in which the concentration of interfering constituents was decreased to negligible levels. Good correlation was observed between this system and conventional spectrophotometry, The immobilized uricase reactor could be re-used for at least 4 months of repeated analysis without loss of activity and was stable if stored at 4 degrees C in 10 mM TRIS-HCl buffer, pH 9.0.
引用
收藏
页码:1775 / 1780
页数:6
相关论文
共 34 条
[1]   Significance of uricase in oxidase-induced oxidative coloring reaction of p-phenylenediamine [J].
Aoki, M ;
Tsujino, Y ;
Kano, K ;
Ikeda, T .
JOURNAL OF ORGANIC CHEMISTRY, 1996, 61 (16) :5610-5616
[2]   FLOW-INJECTION ANALYSIS OF L-LACTATE WITH ENZYME AMPLIFICATION AND AMPEROMETRIC DETECTION [J].
ASOUZU, MU ;
NONIDEZ, WK ;
HO, MH .
ANALYTICAL CHEMISTRY, 1990, 62 (07) :708-712
[3]   DETERMINATION OF PHENOL AND CHLORINATED PHENOLIC-COMPOUNDS BASED ON A PPO-BIOELECTRODE AND ITS INHIBITION [J].
BESOMBES, JL ;
COSNIER, S ;
LABBE, P ;
REVERDY, G .
ANALYTICAL LETTERS, 1995, 28 (03) :405-424
[4]   A SUBSTRATE RECYCLING ASSAY FOR PHENOLIC-COMPOUNDS USING TYROSINASE AND NADH [J].
BROWN, RS ;
MALE, KB ;
LUONG, JHT .
ANALYTICAL BIOCHEMISTRY, 1994, 222 (01) :131-139
[5]   BIOSENSOR BASED ON AN ENZYME-MODIFIED ELECTRODE FOR HIGHLY-SENSITIVE MEASUREMENT OF POLYPHENOLS [J].
EREMENKO, A ;
MAKOWER, A ;
JIN, W ;
RUGER, P ;
SCHELLER, F .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (08) :717-722
[6]  
HANSEN EH, 1991, TALANTA, V38, P75
[7]   Specific and amplified current responses to histidine and histamine using immobilized copper monoamine oxidase membrane electrode, based on novel ascorbate oxidase activity induced by exogenous ligands [J].
Hasebe, Y ;
Toda, S ;
Aoki, K ;
Tonobe, H ;
Uchiyama, S .
ANALYTICAL BIOCHEMISTRY, 1997, 251 (01) :32-38
[8]   HIGHLY AMPLIFIED SPECTROPHOTOMETRY OF POLYPHENOLS BASED ON A CYCLIC REACTION BETWEEN POLYPHENOLS AND O-QUINONE COMPOUNDS USING TYROSINASE AND L-ASCORBIC-ACID [J].
HASEBE, Y ;
TANAKA, Y ;
UCHIYAMA, S .
ANALYTICAL LETTERS, 1994, 27 (01) :41-53
[9]   ENZYME-BASED CHEMICALLY AMPLIFIED FLOW-INJECTION DETERMINATION OF CATECHOL AND CATECHOLAMINES USING AN IMMOBILIZED TYROSINASE REACTOR AND L-ASCORBIC-ACID [J].
HASEBE, Y ;
TAKAMORI, K ;
UCHIYAMA, S .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :363-367
[10]   CHEMICALLY AMPLIFIED ADRENAL-MEDULLA HORMONE SENSOR, BASED ON SUBSTRATE RECYCLING USING TYROSINASE AND L-ASCORBIC-ACID [J].
HASEBE, Y ;
TERATA, S ;
UCHIYAMA, S .
ANALYTICAL SCIENCES, 1993, 9 (06) :855-857