Automated detection of exudates for diabetic retinopathy screening

被引:75
作者
Fleming, Alan D. [1 ]
Philip, Sam [2 ]
Goatman, Keith A. [1 ]
Williams, Graeme J. [2 ]
Olson, John A. [2 ]
Sharp, Peter F. [1 ]
机构
[1] Univ Aberdeen, Aberdeen AB25 2ZD, Scotland
[2] Diabet Retinal Screening Serv, Aberdeen AB25 2ZD, Scotland
关键词
D O I
10.1088/0031-9155/52/24/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Automated image analysis is being widely sought to reduce the workload required for grading images resulting from diabetic retinopathy screening programmes. The recognition of exudates in retinal images is an important goal for automated analysis since these are one of the indicators that the disease has progressed to a stage requiring referral to an ophthalmologist. Candidate exudates were detected using a multi-scale morphological process. Based on local properties, the likelihoods of a candidate being a member of classes exudate, drusen or background were determined. This leads to a likelihood of the image containing exudates which can be thresholded to create a binary decision. Compared to a clinical reference standard, images containing exudates were detected with sensitivity 95.0% and specificity 84.6% in a test set of 13 219 images of which 300 contained exudates. Depending on requirements, this method could form part of an automated system to detect images showing either any diabetic retinopathy or referable diabetic retinopathy.
引用
收藏
页码:7385 / 7396
页数:12
相关论文
共 21 条
[1]  
[Anonymous], 2002, Organisation of Services for Diabetic Retinopathy Screening. Health Technology Assessment Report 1
[2]   LIBSVM: A Library for Support Vector Machines [J].
Chang, Chih-Chung ;
Lin, Chih-Jen .
ACM TRANSACTIONS ON INTELLIGENT SYSTEMS AND TECHNOLOGY, 2011, 2 (03)
[3]   A fully automated comparative microaneurysm digital detection system [J].
Cree, MJ ;
Olson, JA ;
McHardy, KC ;
Sharp, PF ;
Forrester, JV .
EYE, 1997, 11 (5) :622-628
[4]   Screening for diabetic retinopathy using computer based image analysis and statistical classification [J].
Ege, BM ;
Hejlesen, OK ;
Larsen, OV ;
Moller, K ;
Jennings, B ;
Kerr, D ;
Cavan, DA .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2000, 62 (03) :165-175
[5]   Automated assessment of diabetic retinal image quality based on clarity and field definition [J].
Fleming, AD ;
Philip, S ;
Goatman, KA ;
Olson, JA ;
Sharp, PF .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) :1120-1125
[6]   Automatic detection of retinal anatomy to assist diabetic retinopathy screening [J].
Fleming, Alan D. ;
Goatman, Keith A. ;
Philip, Sam ;
Olson, John A. ;
Sharp, Peter F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02) :331-345
[7]   Automated microaneurysm detection using local contrast normalization and local vessel detection [J].
Fleming, Alan D. ;
Philip, Sam ;
Goatman, Keith A. ;
Olson, John A. ;
Sharp, Peter F. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (09) :1223-1232
[8]   Preservation of sight in diabetes: developing a national risk reduction programme [J].
Garvican, L ;
Clowes, J ;
Gillow, T .
DIABETIC MEDICINE, 2000, 17 (09) :627-634
[9]   Automated detection of microaneurysms in digital red-free photographs: a diabetic retinopathy screening tool [J].
Hipwell, JH ;
Strachan, F ;
Olson, JA ;
McHardy, KC ;
Sharp, PF ;
Forrester, JV .
DIABETIC MEDICINE, 2000, 17 (08) :588-594
[10]  
Hsu W, 2001, PROC CVPR IEEE, P246