Analysis of erythromycin and tylosin in bovine muscle using disposable screen printed electrodes

被引:23
作者
Ammida, NHS
Volpe, G
Draisci, R
delli Quadri, F
Palleschi, L
Palleschi, G
机构
[1] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy
[2] Garyounis Univ, Dept Chem, Benghazi, Libya
[3] Ist Super Sanita, Lab Med Vet, I-00161 Rome, Italy
关键词
D O I
10.1039/b308052h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A disposable electrochemical enzyme-linked immunosorbent assay ( ELISA) for the detection of two macrolides ( erythromycin and tylosin) in bovine muscle was developed using a screen printed electrode (SPE) system as a differential pulse voltammetry (DPV) transducer with mouse anti-erythromycin ( and anti-tylosin) monoclonal antibodies (MAb) serving as molecular recognition elements. The immunochemical system makes use of the competition assay principle, and employs an erythromycin (or tylosin) - BSA conjugate as coating molecule. After competition between free and coated analyte for the antibodies, the activity of the alkaline phosphatase labelled antiglobulins was measured electrochemically using 1-naphthylphosphate as substrate. Using standard solutions of erythromycin and tylosin, the detection limit of the assay was 0.2 ng mL(-1) determined to be for erythromycin and 2.0 ng mL(-1) for tylosin, while the sensitivity (25% inhibition concentration) was 1.0 ng mL(-1) for erythromycin and 3.0 ng mL(-1) for tylosin. The suitability of the assay for quantification of erythromycin and tylosin in bovine muscle was also studied. Spiked and real samples were analysed using the immunosensor system developed here. The ELISA showed precision values ( relative standard deviation, RSD%) ranging from 4 to 9% for erythromycin and from 8 to 15% for tylosin; the accuracy ( relative error, RE%) ranged from -11 to 6% and from -4 to 12% for erythromycin and tylosin, respectively. Results obtained on real samples were confirmed by micro-liquid chromatography coupled on line with tandem mass spectrometry (micro-LC-MS-MS), using an atmospheric pressure ionisation (API) source and an ionspray (IS) interface. The latter provides unequivocal identification and quantification of the analytes at the level of interest.
引用
收藏
页码:15 / 19
页数:5
相关论文
共 19 条
[1]  
*AOAC INT, 1995, OFF METH AN AOAC INT
[2]   Microbiological bioassay of erythromycin thiocyanate:: optimisation and validation [J].
Bernabéu, JA ;
Camacho, MA ;
Gil-Alegre, ME ;
Ruz, V ;
Torres-Suárez, AI .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (02) :347-353
[3]   DISPOSABLE RUTHENIZED SCREEN-PRINTED BIOSENSORS FOR PESTICIDES MONITORING [J].
CAGNINI, A ;
PALCHETTI, I ;
LIONTI, I ;
MASCINI, M ;
TURNER, APF .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) :85-89
[4]   Disposable screen-printed electrodes for the immunochemical detection of polychlorinated biphenyls [J].
DelCarlo, M ;
Lionti, I ;
Taccini, M ;
Cagnini, A ;
Mascini, M .
ANALYTICA CHIMICA ACTA, 1997, 342 (2-3) :189-197
[5]  
Delepine B, 1996, J AOAC INT, V79, P397
[6]   IDENTIFICATION OF TYLOSIN IN BOVINE MUSCLE AT THE MAXIMUM RESIDUE LIMIT LEVEL BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY, USING A PARTICLE-BEAM INTERFACE [J].
DELEPINE, B ;
HURTAUD, D ;
SANDERS, P .
ANALYST, 1994, 119 (12) :2717-2721
[7]   A new electrochemical enzyme-linked immunosorbent assay for the screening of macrolide antibiotic residues in bovine meat [J].
Draisci, R ;
delli Quadri, F ;
Achene, L ;
Volpe, G ;
Palleschi, L ;
Palleschi, G .
ANALYST, 2001, 126 (11) :1942-1946
[8]   Confirmatory method for macrolide residues in bovine tissues by micro-liquid chromatography-tandem mass spectrometry [J].
Draisci, R ;
Palleschi, L ;
Ferretti, E ;
Achene, L ;
Cecilia, A .
JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) :97-104
[9]   AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY (ELISA) FOR PLASMA PROGESTERONE - IMMOBILIZED ANTIGEN APPROACH [J].
ELDER, PA ;
YEO, KHJ ;
LEWIS, JG ;
CLIFFORD, JK .
CLINICA CHIMICA ACTA, 1987, 162 (02) :199-206
[10]  
Elks J., 1991, DICT DRUGS