Evaluation of the multi-element capabilities of electrothermal vaporization quadrupole-based ICP mass spectrometry

被引:39
作者
Resano, M [1 ]
Verstraete, M [1 ]
Vanhaecke, F [1 ]
Moens, L [1 ]
机构
[1] State Univ Ghent, Inst Sci Nucl, Analyt Chem Lab, B-9000 Ghent, Belgium
关键词
D O I
10.1039/b101588p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrothermal vaporization (ETV) ICP mass spectrometry is a method that combines the ability or the graphite furnace to handle complex samples with the detection power of ICP-MS. It is somewhat Surprising. however, that most works reporting on the application of this method have only described the "simultaneous" (from the same tube firing) determination of 1-3 elements. Different authors have attributed this fact to the limited capability of the quadrupole filter (the most commonly used mass spectrometer ill ICP-MS instrumentation) to deal with the transient signals that electrothermal vaporization produces. Nevertheless, recent works suggest that the real multi-element capabilities of ETV quadrupole-based ICP-MS might have been largely underestimated. A systematic study of the number of mass-to-charge ratios that call be "simultaneously" monitored in ETV quadrupole-based ICP-MS without degrading the precision, the sensitivity and the limits of detection has been carried out. Three elements with different furnace behaviours (Cd, Co and Ti) were chosen for the study. The effect of the dwell time and the way of processing the analytical data were also evaluated. The results indicate that, when using ETV-ICP-MS with it quadrupole-based instrument, no detrimental effects on the precision, detection limits and sensitivity occur its long its it critical value of three or four points to define the signal profile is achieved. This requirement corresponds to the possibility of monitoring more than 20 elements for a standard peak width of 1.5-2 s. Several options for further improvements are also discussed, including the possibility of separating (with respect to time) the vaporization of elements with different furnace behaviours.
引用
收藏
页码:1018 / 1027
页数:10
相关论文
共 33 条
[1]   QUANTITATIVE EVALUATION OF CHROMATOGRAMS BY DIGITAL COMPUTERS [J].
BAUMANN, F ;
HERLICSK.E ;
BROWN, AC ;
BLESCH, J .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1969, 7 (11) :680-&
[2]   Observation, identification and correction of structured molecular background by means of continuum source AAS - determination of selenium and arsenic in human urine [J].
Becker-Ross, H ;
Florek, S ;
Heitmann, U .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (02) :137-141
[3]   OCCURRENCE AND REDUCTION OF NOISE IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR ENHANCED PRECISION IN ISOTOPE RATIO MEASUREMENT [J].
BEGLEY, IS ;
SHARP, BL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :171-176
[4]  
Bettinelli M, 2000, ATOM SPECTROSC, V21, P195
[5]  
Byrne JP, 1998, ATOM SPECTROSC, V19, P116
[6]   VAPORIZATION AND ATOMIZATION OF BORON IN THE GRAPHITE-FURNACE INVESTIGATED BY ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
BYRNE, JP ;
GREGOIRE, DC ;
GOLTZ, DM ;
CHAKRABARTI, CL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (05) :433-443
[7]   EFFECT OF PEAK SENSING AND RANDOM NOISE ON PRECISION AND ACCURACY OF STATISTICAL MOMENT ANALYSES FROM DIGITAL CHROMATOGRAPHIC DATA [J].
CHESLER, SN ;
CRAM, SP .
ANALYTICAL CHEMISTRY, 1971, 43 (14) :1922-&
[8]   Slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry for steelmaking flue dust analysis [J].
Coedo, AG ;
Dorado, T ;
Padilla, I ;
Maibusch, R ;
Kuss, HM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (02) :185-196
[9]   A STUDY OF THE FORMATION OF ATOMS AND DRY AEROSOLS ABOVE A GRAPHITE ROD SAMPLE INTRODUCTION USED FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
DEAN, JR ;
SNOOK, RD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (06) :461-465
[10]  
DENOYER ER, 1994, ATOM SPECTROSC, V15, P7