Slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry for steelmaking flue dust analysis

被引:25
作者
Coedo, AG
Dorado, T
Padilla, I
Maibusch, R
Kuss, HM
机构
[1] CENIM, Madrid 28040, Spain
[2] Univ Duisburg Gesamthsch, D-47057 Duisburg, Germany
关键词
electrothermal vaporization; inductively coupled plasma mass spectrometry; slurry sampling; steelmaking flue dusts;
D O I
10.1016/S0584-8547(99)00179-2
中图分类号
O433 [光谱学];
学科分类号
0703 [化学]; 070302 [分析化学];
摘要
A commercial atomic absorption graphite furnace (AAGF), with a self-made adapter and valve system, was used as a slurry sampling cell for electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). The system was applied to the determination of As, Sn, Sb, Se, Te, Bi, Cd, V, Ti and Mo in steelmaking flue dusts. Experimental conditions with respect to ETV and ICP-MS operating parameters were optimized. Compared to aqueous solutions, slurry samples were found to present better analyte transport. Microgram amounts of Rh were used to reduce the difference in analyte response in sensitivity, for aqueous solutions of the tested analytes. No such increasing effect was observed for slurry samples and aqueous standards. An added quantity of Rh acting as modifier/carrier resulted in an increase for the same analytes in matrix-slurry solutions, even the addition of an extra Rh quantity has resulted in a decrease in the signals. The effect of Triton X-100 (used as a dispersant agent) on analyte intensity and precision was also studied. External calibration from aqueous standards spiked with 100 mu g ml(-1) Rh was performed to quantified 0.010 g/100 ml slurry samples. Results are presented for a certified reference electrical are furnace flue dust (EAF): CRM-876-1 (Bureau of Analysis Samples Ltd., Cleveland, UK), a reference sample of coke ashes X-3705 (from AG der Dillinger Huttenwerke, Germany), and a representative sample of EAF flue dust from a Spanish steelmaking company (CENIM-1). For the two reference materials an acceptable agreement with certificate values was achieved, and the results for the CENIM sample matched with those obtained from conventional nebulization solution. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:185 / 196
页数:12
相关论文
共 22 条
[1]
APPLICATION OF PALLADIUM-PLATING AND RHODIUM-PLATING OF THE GRAPHITE-FURNACE IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BULSKA, E ;
JEDRAL, W .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (01) :49-53
[2]
Determination of arsenic, selenium and mercury in fish samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Chen, SF ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (07) :673-677
[3]
Determination of cadmium, mercury and lead in soil samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Chen, SF ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (10) :1113-1117
[4]
Evaluation of a desolvating microconcentric nebulizer in inductively coupled plasma mass spectrometry to improve the determination of arsenic in steels [J].
Coedo, AG ;
Dorado, T ;
Padilla, I .
APPLIED SPECTROSCOPY, 1999, 53 (08) :974-978
[5]
Coedo AG, 1996, J TRACE MICROPROBE T, V14, P739
[6]
Slurry nebulization in plasmas [J].
Ebdon, L ;
Foulkes, M ;
Sutton, K .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) :213-229
[7]
THE ROLE OF CHEMICAL MODIFIERS IN ANALYTE TRANSPORT LOSS INTERFERENCES WITH ELECTROTHERMAL VAPORIZATION ICP-MASS SPECTROMETRY [J].
EDIGER, RD ;
BERES, SA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (07) :907-922
[8]
ANALYTE TRANSPORT STUDIES OF AQUEOUS-SOLUTIONS AND SLURRY SAMPLES USING ELECTROTHERMAL VAPORIZATION ICP-MS [J].
FONSECA, RW ;
MILLERIHLI, NJ .
APPLIED SPECTROSCOPY, 1995, 49 (10) :1403-1410
[9]
DIRECT ANALYSIS OF SOLIDS BY ULTRASONIC SLURRY ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
GREGOIRE, DC ;
MILLERIHLI, NJ ;
STURGEON, RE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (05) :605-610
[10]
Determination of trace impurities in high-purity quartz by electrothermal vaporization inductively coupled plasma mass spectrometry using the slurry sampling technique [J].
Hauptkorn, S ;
Krivan, V ;
Gercken, B ;
Pavel, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) :421-428