Five-year experience with Crossfire® highly cross-linked polyethylene

被引:106
作者
D'Antonio, JA
Manley, MT
Capello, WN
Bierbaum, BE
Ramakrishnan, R
Naughton, M
Sutton, K
机构
[1] Greater Pittsburgh Orthopaed Assoc, Moon Township, PA USA
[2] Clin Measurement Corp, Ridgewood, NJ USA
[3] Indiana Univ, Sch Med, Indianapolis, IN USA
[4] New England Baptist Hosp, Boston, MA USA
[5] Stryker Orthopaed, Mahwah, NJ USA
关键词
D O I
10.1097/01.blo.0000194090.77500.b4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Our purpose was to compare the clinical wear performance of highly cross-linked (Crossfire (R)) polyethylene with conventional (N2Vac (TM)) polyethylene total hip bearings. We implanted 56 hips (47 patients) with Crossfire (R) acetabular bearing liners and compared their wear performance with 53 conventional polyethylene inserts. Wear and clinical data were collected retrospectively at a minimum 4-year and average 5-year followup. The linear femoral head penetration rate measured from plain radiographs was 0.055 mm/year +/- 0.022 mm/year for the Crossfire (R) polyethylene and 0.138 mm/year 0.073 mm/year for the control, a reduction of 60% for the Crossfire (R) components. Calculated annual wear was 0.036 mm/year for the Crossfire (R) components and 0.131 mm/year for the controls, a reduction of 72%. Radiographic review at most recent followup showed a reduction in erosive osteolytic lesions of the proximal femur for the Crossfire (R) components compared with controls, also suggesting a reduction in debris release for the Crossfire (R) components. Complications leading to revision were not seen in the Crossfire (R) or control groups. These clinical findings suggest that this particular highly cross-linked polyethylene can provide wear reduction and an alternate bearing surface for active patient populations. Level of Evidence: Therapeutic study, Level III (retrospective comparative study). See the Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 32 条
[1]
Ultra high molecular-weight polyethylene (UHMWPE) in total knee replacement: Fabrication, sterilisation and wear [J].
Blunn, G ;
del Preva, EMB ;
Costa, L ;
Fisher, J ;
Freeman, MAR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (07) :946-949
[2]
Charnley total hip arthroplasty with cement - Minimum twenty-five-year follow-up [J].
Callaghan, JJ ;
Albright, JC ;
Goetz, DD ;
Olejniczak, JP ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (04) :487-497
[3]
Comparison of cross-linked polyethylene materials for orthopaedic applications [J].
Collier, JP ;
Currier, BH ;
Kennedy, FE ;
Currier, JH ;
Timmins, GS ;
Jackson, SK ;
Brewer, RL .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (414) :289-304
[4]
Alumina ceramic bearings for total hip arthroplasty - Five-year results of a prospective randomized study [J].
D'Antonio, J ;
Capello, W ;
Manley, M ;
Naughton, M ;
Sutton, K .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :164-171
[5]
Highly cross-linked polyethylene in cemented THA -: Randomized study of 61 hips [J].
Digas, G ;
Kärrholm, J ;
Thanner, J ;
Malchau, H ;
Herberts, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :126-138
[6]
A literature review of the association between wear rate and osteolysis in total hip arthroplasty [J].
Dumbleton, JH ;
Manley, MT ;
Edidin, AA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (05) :649-661
[7]
Engh CA., 1990, CLIN ORTHOP RELAT R, V257, P107
[8]
Gomez-Barrena E, 1998, CLIN ORTHOP RELAT R, P105
[9]
Early osteolysis with Hylamer acetabular liners [J].
Graeter, JH ;
Nevins, R .
JOURNAL OF ARTHROPLASTY, 1998, 13 (04) :464-466
[10]
HARRIS WH, 1995, CLIN ORTHOP RELAT R, P46