Determination of lasalocid with sensitized terbium(III) luminescence detection

被引:12
作者
Aguilar-Caballos, MP [1 ]
Gómez-Hens, A [1 ]
Pérez-Bendito, D [1 ]
机构
[1] Univ Cordoba, Fac Sci, Dept Analyt Chem, E-14004 Cordoba, Spain
关键词
lasalocid; lanthanide-sensitized luminescence; kinetic and equilibrium methods; stopped-flow technique; samples analysis;
D O I
10.1016/S0039-9140(98)00240-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The luminescence of the lasalocid-terbium(III) system in the presence of Triton X-100 and trioctylphosphine oxide has been studied by obtaining kinetic and equilibrium measurements and using the stopped-flow mixing technique. The initial rate and luminescence signal of this system are directly proportional to the lasalocid concentration, which allows one to develop very simple, fast, automatic methods for the determination of this analyte. Kinetic and equilibrium data can be obtained in only 0.1 and 10 s, respectively. The calibration graphs were linear over the range 0.004-5.0 mu g ml(-1) (kinetic method) and 0.01-5.0 mu g ml(-1) (equilibrium method) and the detection limits achieved were 1 and 3 ng ml(-1), respectively, equivalent to 2 and 6 ng g(-1) lasalocid in a chicken liver sample, which are similar to those afforded by the chromatographic methods described for this determination. The relative standard deviation of both methods was close to 2%. The analytical recoveries obtained by applying the kinetic and equilibrium methods to drinking water, poultry feed and chicken liver samples ranged from 95.6 to 102.1% and from 95.9 to 104.9%, respectively. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:209 / 217
页数:9
相关论文
共 21 条
[1]   IMPROVEMENT OF CHEMICAL-ANALYSIS OF ANTIBIOTICS .20. BASIC STUDY ON HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF 4 POLYETHER ANTIBIOTICS PRE-DERIVATIZED WITH 1-BROMOACETYLPYRENE [J].
ASUKABE, H ;
MURATA, H ;
HARADA, KI ;
SUZUKI, M ;
OKA, H ;
IKAI, Y .
JOURNAL OF CHROMATOGRAPHY A, 1993, 657 (02) :349-356
[2]   IMPROVEMENT OF CHEMICAL-ANALYSIS OF ANTIBIOTICS .11. SIMULTANEOUS FLUORODENSITOMETRIC DETERMINATION OF POLYETHER ANTIBIOTICS [J].
ASUKABE, H ;
YONEYAMA, H ;
MORI, Y ;
HARADA, KI ;
SUZUKI, M ;
OKA, H .
JOURNAL OF CHROMATOGRAPHY, 1987, 396 :261-271
[3]   IMPROVEMENT OF CHEMICAL-ANALYSIS OF ANTIBIOTICS .21. SIMULTANEOUS DETERMINATION OF 3 POLYETHER ANTIBIOTICS IN FEEDS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
ASUKABE, H ;
MURATA, H ;
HARADA, K ;
SUZUKI, M ;
OKA, H ;
IKAI, Y .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1994, 42 (01) :112-117
[4]   DETERMINATION OF LASALOCID IN EGGS USING LIQUID CHROMATOGRAPHY-ELECTROSPRAY MASS-SPECTROMETRY [J].
BLANCHFLOWER, WJ ;
KENNEDY, DG .
ANALYST, 1995, 120 (04) :1129-1132
[5]  
FRANK LR, 1989, J ASSOC OFF ANA CHEM, V72, P584
[6]   DETERMINATION OF IONOPHORES IN THE TISSUES OF FOOD ANIMALS BY LIQUID-CHROMATOGRAPHY [J].
GERHARDT, GC ;
SALISBURY, CDC ;
CAMPBELL, HM .
FOOD ADDITIVES AND CONTAMINANTS, 1995, 12 (06) :731-737
[7]  
HORIL S, 1990, J LIQ CHROMATOGR, V13, P1411
[8]   LASALOCID DETERMINATION IN ANIMAL BLOOD BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FLUORESCENCE DETECTION [J].
KAYKATY, M ;
WEISS, G .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1983, 31 (01) :81-84
[9]  
Long GL, 1983, ANAL CHEM, V55, p712A, DOI [DOI 10.1021/AC00258A001, 10.1021/ac00258a001]
[10]  
MARTINEZ EE, 1986, J ASSOC OFF ANA CHEM, V69, P637