Interscalene perineural ropivacaine infusion: A comparison of two dosing regimens for postoperative analgesia

被引:55
作者
Ilfeld, BM
Morey, TE
Wright, TW
Chidgey, LK
Enneking, FK
机构
[1] Univ Florida, Dept Anesthesiol, Gainesville, FL 32610 USA
[2] Univ Florida, Dept Orthoped & Rehabil, Gainesville, FL USA
关键词
ambulatory surgery; continuous nerve block; continuous interscalene block; patient-controlled regional analgesia; perineural local anesthetic infusion; postoperative analgesia;
D O I
10.1016/j.rapm.2003.08.016
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives: A continuous interscalene nerve block with a perineural infusion of ropivacaine 0.2% at 8 mL/h has been shown to provide potent analgesia following moderately painful shoulder surgery. However, this high basal rate limits infusion duration for ambulatory patients who must carry the local anesthetic reservoir. We undertook this investigation to determine if the basal rate of an interscalene perineural ropivacaine infusion could be decreased by 50% with a concurrent 200% increase in patient-controlled bolus dose without compromising infusion benefits in ambulatory patients undergoing moderately painful orthopedic shoulder surgery. Methods: Preoperatively, patients (n = 24) received an interscalene perineural catheter and nerve block. Intraoperatively, patients received a standardized general anesthetic. Postoperatively, patients were discharged home with a portable infusion pump delivering ropivacaine 0.2% (5 00 mL reservoir) with a basal rate of 8 mL/h and a 2 mL patient-controlled bolus available each hour ("8/2" group, n = 12) or a 4 mL/h basal rate and 6 mL bolus dose ("4/6" group, n = 12), delivered in a randomized, double-blinded manner. Results: Patients in the 4/6 group had higher baseline pain scores only on postoperative day (POD) 2 (P = .011). However, these patients also experienced an increase in breakthrough pain incidence (5.8 boluses/d v 3.2, P = .035) and intensity ("worst" pain = 8/10 v 4/10, P < .05), sleep disturbances (2.0 v 0.0, P < .001), and a decrease in analgesia satisfaction (8 v 10, P = .003). Patients in the 8/2 group exhausted their local anesthetic reservoirs after a median of 61 hours, while the 4/6 group had a median of 131 mL remaining at infusion discontinuation after a median of 75 hours (P < .001). Conclusions: Following moderately painful ambulatory shoulder surgery, decreasing an interscalene perineural ropivacaine 0.2% basal rate from 8 to 4 mL/h provides similar baseline analgesia and lengthens infusion duration, but compromises other infusion benefits.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 26 条
[1]   Psoas abscess complicating femoral nerve block catheter [J].
Adam, F ;
Jaziri, S ;
Chauvin, M .
ANESTHESIOLOGY, 2003, 99 (01) :230-231
[2]   A new technique of continuous interscalene nerve block [J].
Boezaart, AP ;
de Beer, JF ;
du Toit, C ;
van Rooyen, K .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (03) :275-281
[3]   Acute and nonacute complications associated with interscalene block and shoulder surgery - A prospective study [J].
Borgeat, A ;
Ekatodramis, G ;
Kalberer, F ;
Benz, C .
ANESTHESIOLOGY, 2001, 95 (04) :875-880
[4]   Patient-controlled analgesia after major shoulder surgery - Patient-controlled interscalene analgesia versus patient-controlled analgesia [J].
Borgeat, A ;
Schappi, B ;
Biasca, N ;
Gerber, C .
ANESTHESIOLOGY, 1997, 87 (06) :1343-1347
[5]  
Borgeat A, 2001, ANESTH ANALG, V92, P218
[6]   Patient-controlled interscalene analgesia with ropivacaine after major shoulder surgery: PCIA vs PCA [J].
Borgeat, A ;
Tewes, E ;
Biasca, N ;
Gerber, C .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 81 (04) :603-605
[7]   Patient-controlled interscalene analgesia with ropivacaine 0.2% versus patient-controlled intravenous analgesia after major shoulder surgery - Effects on diaphragmatic and respiratory function [J].
Borgeat, A ;
Perschak, H ;
Bird, P ;
Hodler, J ;
Gerber, C .
ANESTHESIOLOGY, 2000, 92 (01) :102-108
[8]   Patient-controlled perineural analgesia after ambulatory orthopedic surgery: A comparison of electronic versus elastomeric pumps [J].
Capdevila, X ;
Macaire, P ;
Aknin, P ;
Dadure, C ;
Bernard, N ;
Lopez, S .
ANESTHESIA AND ANALGESIA, 2003, 96 (02) :414-417
[9]   UNSUSPECTED EXTRADURAL CATHETERIZATION IN AN INTERSCALENE BLOCK [J].
COOK, LB .
BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (04) :473-475
[10]   The continuous femoral nerve block catheter for postoperative analgesia: Bacterial colonization, infectious rate and adverse effects [J].
Cuvillon, P ;
Ripart, J ;
Lalourcey, L ;
Veyrat, E ;
L'Hermite, J ;
Boisson, C ;
Thouabtia, E ;
Eledjam, JJ .
ANESTHESIA AND ANALGESIA, 2001, 93 (04) :1045-1049