A randomized, controlled, multi-center trial comparing the safety and efficacy of zotarolimus-eluting and paclitaxel-eluting stents in de novo lesions in coronary arteries: Final results of the ZoMaxx II trial

被引:4
作者
Gray, William A. [2 ]
Yeung, Alan C. [3 ]
Cutlip, Donald E. [4 ]
Popma, Jeffrey J. [5 ]
Fitzgerald, Peter J. [3 ]
Williams, David O. [6 ]
Heuer, Hubertus [7 ]
O'Shaughnessy, Charles D. [8 ]
Overlie, Paul A. [9 ]
Mann, J. Tift [10 ]
Cannon, Louis A. [11 ]
Hermiller, James B. [12 ]
Henry, Timothy D. [13 ]
Whitbourn, Robert [14 ]
Stuckey, Thomas D. [15 ]
Midei, Mark G. [16 ]
Coe, Jessie [1 ]
Schwartz, Lewis B. [1 ]
机构
[1] Abbott Labs, Abbott Pk, IL 60064 USA
[2] Columbia Univ, Med Ctr, New York, NY USA
[3] Stanford Univ, Med Ctr, Palo Alto, CA 94304 USA
[4] Harvard Clin Res Inst, Boston, MA USA
[5] Brigham & Womens Hosp, Boston, MA 02115 USA
[6] Rhode Isl Hosp, Providence, RI USA
[7] St Johannes Hosp, Dortmund, Germany
[8] Eyria Mem Hosp, Reg Med Ctr, Elyria, OH USA
[9] Lubbock Heart Hosp, Lubbock, TX USA
[10] Wake Med Hosp, Raleigh, NC USA
[11] No Michigan Hosp, Petoskey, MI USA
[12] Heart Ctr Indianapolis, Indianapolis, IN USA
[13] Abbott NW Hosp, Minneapolis, MN 55407 USA
[14] St Vincents Hosp, Melbourne, Vic, Australia
[15] Moses Cone Mem Hosp, Greensboro, NC USA
[16] St Joseph Med Ctr, Towson, MD USA
关键词
Zotarolimus; Drug-eluting stents; Percutaneous coronary intervention; Restenosis; CLINICAL-OUTCOMES; COATED STENT; FOLLOW-UP; REVASCULARIZATION; IMPLANTATION; EVALUATE; DISEASE;
D O I
10.1016/j.ijcard.2011.05.061
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: The purpose of this prospective, randomized, single-blind controlled clinical trial was to compare the effectiveness of a zotarolimus-eluting stent (ZoMaxx (TM)) with a paclitaxel-eluting coronary stent (Taxus (TM) Express(2)(TM)) in patients with angina pectoris and a single native coronary artery lesion between 10-28 mm in length and 2.5-3.75 mm in diameter. Methods: Patients were enrolled at 75 international institutions between June 2005 and November 2006. Results: 1099 (1672 originally planned) patients received 557 ZoMaxx and 542 Taxus stents: cohorts were well-matched for diabetes (27% vs. 27%), reference vessel diameter (2.73 +/- 0.46 mm vs. 2.74 +/- 0.45 mm) and lesion length (14.8 +/- 6.7 mm vs. 14.3 +/- 6.4 mm). Nine month clinical and angiographic follow-up was available in 1052/1099 (96%) and 649/836 (78%) patients, respectively. The safety profiles for the two stents (myocardial infarction (MI), cardiac death and/or target vessel revascularization (TVR)) were similar (ZoMaxx 8.7% vs. Taxus 6.9%, p = NS). The primary endpoint of 9-month TVR occurred more frequently after treatment with ZoMaxx (6.8%) as compared with Taxus (4.2%), therefore the primary clinical endpoint was not met. However, the 9-month in-segment late lumen loss for ZoMaxx (0.29 +/- 0.47 mm) and Taxus (0.22 +/- 0.41 mm, p = NS) were similar, thus satisfying the primary angiographic endpoint. Secondary endpoints of the rates of in-segment and in-stent binary restenosis were also similar (5.9% vs. 5.8%, 7.8% vs. 7.9%, respectively). Conclusions: At 9 months, the ZoMaxx stent failed to achieve the primary endpoint of non-inferiority in TVR to the Taxus stent, but safety endpoints were equal between the two stent systems. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 43 条
[1]   Clinical and angiographic results of percutaneous coronary revascularization using a trilayer stainless steel-tantalum-stainless steel phosphorylcholine-coated stent: The Trimaxx trial [J].
Abizaid, Alexandre ;
Popma, Jeffrey J. ;
Tanajura, Luis F. ;
Hattori, Kyoko ;
Solberg, Brad ;
Larracas, Cristina ;
Feres, Fausto ;
Costa, Jose de Ribamar, Jr. ;
Schwartz, Lewis B. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (07) :914-919
[2]   Percutaneous coronary revascularization using a trilayer metal phosphorylcholine-coated zotarolimus-eluting stent [J].
Abizaid, Alexandre ;
Lansky, Alexandra J. ;
Fitzgerald, Peter J. ;
Tanajura, Luis Fernando ;
Feres, Fausto ;
Staico, Rodolfo ;
Mattos, Luiz ;
Abizaid, Andrea ;
Chaves, Aurea ;
Centemero, Marinella ;
Sousa, Amanda G. M. R. ;
Sousa, J. Eduardo ;
Zaugg, Margo J. ;
Schwartz, Lewis B. .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (10) :1403-1408
[3]  
BOLAND JL, 2000, INT J CARDIOVASC INT, V3, P215
[4]  
Bridges J, 2009, MED DEVICES-EVID RES, V2, P1
[5]   Zotarolimus (ABT-578) eluting stents [J].
Burke, Sandra E. ;
Kuntz, Richard E. ;
Schwartz, Lewis B. .
ADVANCED DRUG DELIVERY REVIEWS, 2006, 58 (03) :437-446
[6]   Biocompatible surfaces using methacryloylphosphorylcholine laurylmethacrylate copolymer [J].
Campbell, E.J. ;
O'Byrne, V. ;
Stratford, P.W. ;
Quirk, I. ;
Vick, T.A. ;
Wiles, M.C. ;
Yianni, Y.P. .
ASAIO Journal, 1994, 40 (03)
[7]   Zotarolimus, a novel Sirolimus analogue with potent anti-proliferative activity on coronary smooth muscle cells and reduced potential for systemic immunosuppression [J].
Chen, Yung-Wu ;
Smith, Morey L. ;
Sheets, Michael ;
Ballaron, Steve ;
Trevillyan, James M. ;
Burke, Sandra E. ;
Rosenberg, Teresa ;
Henry, Cindy ;
Wagner, Rolf ;
Bauch, Joy ;
Marsh, Kennan ;
Fey, Thomas A. ;
Hsieh, Gin ;
Gauvin, Donna ;
Mollison, Karl W. ;
Carter, George W. ;
Djuric, Stevan W. .
JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 2007, 49 (04) :228-235
[8]  
Chevalier B, 2006, RANDOMIZED CONTROLLE
[9]   A Randomized, Controlled, Multicenter Trial to Evaluate the Safety and Efficacy of Zotarolimus-Versus Paclitaxel-Eluting Stents in De Novo Occlusive Lesions in Coronary Arteries The ZoMaxx I Trial [J].
Chevalier, Bernard ;
Di Mario, Carlo ;
Neumann, Franz-Josef ;
Ribichini, Flavio ;
Urban, Philip ;
Popma, Jeffrey J. ;
Fitzgerald, Peter J. ;
Cutlip, Donald E. ;
Williams, David O. ;
Ormiston, John ;
Grube, Eberhard ;
Whitbourn, Robert ;
Schwartz, Lewis B. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (05) :524-532
[10]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351