Three-dimensional echocardiography; Speckle tracking; Ventricular function; CARDIAC RESYNCHRONIZATION; QUANTITATIVE-EVALUATION; 2-DIMENSIONAL STRAIN; VALIDATION; HEART; QUANTIFICATION; DYSSYNCHRONY; STATEMENT; ROTATION; FIBROSIS;
D O I
10.1016/j.echo.2011.04.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Myocardial deformation measurements using two-dimensional speckle-tracking echocardiography (STE) are known to vary among vendors. The intervendor agreement of three-dimensional (3D) deformation indices has not been studied. The goals of this study were to determine the intervendor agreement of 3D STE-based measurements of left ventricular (LV) deformation parameters to investigate the intrinsic variability of these measurements and identify the sources of intervendor differences. Methods: Real-time full-volume images obtained in 30 subjects with normal LV systolic function using two vendors' equipment (V1 and V2) on the same day were analyzed by two independent observers using two software packages (S1 and S2). Agreement between three technique combinations (V1/S1, V2/S2, and V1/S2) and their intrinsic reproducibility (interobserver and intraobserver agreement) were assessed using intraclass correlation coefficients. Parameters of LV deformation included global longitudinal strain, twist, 3D displacement, and 3D strain and its radial, longitudinal, and circumferential components. Results: For all three combinations, intertechnique agreement was poor (intraclass correlation coefficient < 0.4), always beyond the intrinsic variability. For all measured parameters, the intertechnique agreement was better when the same software package was used with images from different vendors (V2/S2 vs V1/S2) than when images from same vendor were analyzed using different software (V1/S2 vs V1/S1). Conclusions: Three-dimensional STE-derived LV deformation parameters are highly vendor dependent, and the discordance levels are beyond intrinsic measurement variability of any of the tested combinations of imaging equipment and analysis software. This intervendor discordance must be taken into account when interpreting 3D deformation data. (J Am Soc Echocardiogr 2011; 24: 878-85.)
引用
收藏
页码:878 / 885
页数:8
相关论文
共 19 条
  • [11] Three-Dimensional-Wall Motion Tracking: A New and Faster Tool for Myocardial Strain Assessment: Comparison With Two-Dimensional-Wall Motion Tracking
    Perez de Isla, Leopoldo
    Vivas Balcones, David
    Fernandez-Golfin, Covadonga
    Marcos-Alberca, Pedro
    Almeria, Carlos
    Luis Rodrigo, Jose
    Macaya, Carlos
    Zamorano, Jose
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (04) : 325 - 330
  • [12] Experimental validation of circumferential, longitudinal, and radial 2-dimensional strain during dobutamine stress echocardlography in ischemic conditions
    Reant, Patricia
    Labrousse, Louis
    Lafitte, Stephane
    Bordachar, Pierre
    Pillois, Xavier
    Tariosse, Liliane
    Bonoron-Adele, Simone
    Padois, Philippe
    Deville, Claude
    Roudaut, Raymond
    Dos Santos, Pierre
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (02) : 149 - 157
  • [13] Comprehensive Evaluation of Left Ventricular Strain Using Speckle Tracking Echocardiography in Normal Adults: Comparison of Three-Dimensional and Two-Dimensional Approaches
    Saito, Ken
    Okura, Hiroyuki
    Watanabe, Nozomi
    Hayashida, Akihiro
    Obase, Kikuko
    Imai, Koichiro
    Maehama, Tomoko
    Kawamoto, Takahiro
    Neishi, Yoji
    Yoshida, Kiyoshi
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (09) : 1025 - 1030
  • [14] Global and regional myocardial function quantification by two-dimensional strain - Application in hypertrophic cardiomyopathy
    Serri, K
    Reant, P
    Lafitte, M
    Berhouet, M
    Le Bouffos, V
    Roudaut, R
    Lafitte, S
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) : 1175 - 1181
  • [15] INTRACLASS CORRELATIONS - USES IN ASSESSING RATER RELIABILITY
    SHROUT, PE
    FLEISS, JL
    [J]. PSYCHOLOGICAL BULLETIN, 1979, 86 (02) : 420 - 428
  • [16] Novel speckle-tracking radial strain from routine black-and-white echocardiographic images to quantify dyssynchrony and predict response to cardiac resynchronization therapy
    Suffoletto, MS
    Dohi, K
    Cannesson, M
    Saba, S
    Gorcsan, J
    [J]. CIRCULATION, 2006, 113 (07) : 960 - 968
  • [17] A new echocardiographic approach for the detection of non-ischaemic fibrosis in hypertrophic myocardium
    Weidemann, Frank
    Niemann, Markus
    Herrmann, Sebastian
    Kung, Margret
    Stoerk, Stefan
    Waller, Christiane
    Beer, Meinrad
    Breunig, Frank
    Wanner, Christoph
    Voelker, Wolfram
    Ertl, Georg
    Bijnens, Bart
    Strotmann, Joerg M.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 (24) : 3020 - 3026
  • [18] Impact of Myocardial Fibrosis in Patients With Symptomatic Severe Aortic Stenosis
    Weidemann, Frank
    Herrmann, Sebastian
    Stoerk, Stefan
    Niemann, Markus
    Frantz, Stefan
    Lange, Volkmar
    Beer, Meinrad
    Gattenloehner, Stefan
    Voelker, Wolfram
    Ertl, Georg
    Strotmann, Joerg M.
    [J]. CIRCULATION, 2009, 120 (07) : 577 - 584
  • [19] Three-Dimensional Speckle-Tracking Imaging for Left Ventricular Rotation Measurement An In Vitro Validation Study
    Zhou, Zhiwen
    Ashraf, Muhammad
    Hu, Dayi
    Dai, Xiaonan
    Xu, Yawei
    Kenny, Bill
    Cameron, Berkley
    Nguyen, Thuan
    Xiong, Li
    Sahn, David J.
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (06) : 903 - 909