Current status of the glucose sensor

被引:11
作者
Meyerhoff, C [1 ]
Mennel, FJ [1 ]
Sternberg, F [1 ]
Pfeiffer, EF [1 ]
机构
[1] UNIV ULM,INST DIABET TECHNOL,D-89081 ULM,GERMANY
关键词
D O I
10.1097/00019616-199601000-00008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study gives an overview of glucose sensing strategies for potential use in diabetes therapy. The basis for the most commonly used amperometric glucosensors is the Clark electrode which measures oxygen tension. Coupling this sensor with glucose oxidase led to the first specific ''biosensor'' for glucose measurement. This sensor has been used for more than 20 years in the in vitro artificial pancreas (''Biostator''). The development of implantable glucose sensors has been hampered by the disappointing in vivo behavior of these sensors. Alternative glucose sensing techniques including noninvasive approaches are still experimental. Combining the microdialysis technique for continuous sampling of subcutaneous extracellular fluid with an in vitro on-line amperometric glucose oxidase electrode (the ''Ulmer Zuckeruhr'' or ''sugar watch'' system), permits continuous glucose sensing for 72 hours. Although there are differences and delays between changes in tissue and blood glucose concentrations, a complete automated feedback controlled insulin delivery system is possible if fast acting insulin analogs can close the insulin delivery ''feedback loop.''
引用
收藏
页码:51 / 58
页数:8
相关论文
共 29 条
[1]  
ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
[2]   ARTIFICIAL ENDOCRINE PANCREAS [J].
ALBISSER, AM ;
LEIBEL, BS ;
EWART, TG ;
DAVIDOVAC, Z ;
BOTZ, CK ;
ZINGG, W .
DIABETES, 1974, 23 (05) :389-396
[3]   CONCENTRATIONS OF FREE AMINO ACIDS AND OTHER ELECTROLYTES IN CEREBROSPINAL FLUID IN VIVO DIALYSATE OF BRAIN AND BLOOD PLASMA OF DOG [J].
BITO, L ;
DAVSON, H ;
LEVIN, E ;
MURRAY, M ;
SNIDER, N .
JOURNAL OF NEUROCHEMISTRY, 1966, 13 (11) :1057-&
[4]   PROGRESS IN PRACTICAL ENDOCRINOLOGY - THE GLUCOSENSOR UNITEC ULM - A PORTABLE MONITOR FOR CONTINUOUS BLOOD-GLUCOSE MEASUREMENT [J].
BRUCKEL, J ;
ZIER, H ;
KERNER, W ;
PFEIFFER, EF .
HORMONE AND METABOLIC RESEARCH, 1990, 22 (07) :382-384
[5]   STEADY-STATE THEORY FOR QUANTITATIVE MICRODIALYSIS OF SOLUTES AND WATER INVIVO AND INVITRO [J].
BUNGAY, PM ;
MORRISON, PF ;
DEDRICK, RL .
LIFE SCIENCES, 1990, 46 (02) :105-119
[6]  
CLARK LC, 1956, T AM SOC ART INT ORG, V2, P41
[7]  
CZABAN JD, 1985, ANAL CHEM, V57, pA345
[8]  
DELGADO JMR, 1972, ARCH INT PHARMACOD T, V198, P9
[9]   COMBINATION OF MICRODIALYSIS AND GLUCOSENSOR PERMITS CONTINUOUS (ON LINE) SC GLUCOSE MONITORING IN A PATIENT OPERATED DEVICE .1. INVITRO EVALUATION [J].
KECK, FS ;
KERNER, W ;
MEYERHOFF, C ;
ZIER, H ;
PFEIFFER, EF .
HORMONE AND METABOLIC RESEARCH, 1991, 23 (12) :617-618
[10]   THE FUNCTION OF A HYDROGEN PEROXIDE-DETECTING ELECTROENZYMATIC GLUCOSE ELECTRODE IS MARKEDLY IMPAIRED IN HUMAN SUB-CUTANEOUS TISSUE AND PLASMA [J].
KERNER, W ;
KIWIT, M ;
LINKE, B ;
KECK, FS ;
ZIER, H ;
PFEIFFER, EF .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) :473-482