Source follower or charge amplifier? An experimental comparison using a detector with integrated electronics

被引:14
作者
Sampietro, M
Fasoli, L
Bertuccio, G
机构
[1] Politecnico di Milano, Dipartimento di Elettronica E Informazione, 20133 Milano
关键词
D O I
10.1109/23.531790
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In spectroscopy systems where the front-end amplifier is an external circuit, charge sensitive preamplifiers have been shown to be superior in performance with respect to voltage amplifiers as the first stage of amplification, The paper studies how these two circuit configurations behave when they are integrated in high resolution semiconductor detectors of very small capacitance, This paper for the first time compares, in this new condition, the stability of amplification of the source follower with the optimum behavior of the charge preamplifier, reporting its dependence on the detector bias, on the input transistor bias, and on the operating temperature, This paper then discusses the consequent loss in linearity and resolution that a system with an integrated source follower may undergo depending on the type of reset mechanism, The point of how the instabilities of the integrated feedback capacitance limit the performance of an integrated charge amplifier is also addressed, The analysis is based on experimental results obtained with the same detector with integrated electronics used in the two different configurations.
引用
收藏
页码:2413 / 2418
页数:6
相关论文
共 12 条
[1]   A NOVEL CHARGE SENSITIVE PREAMPLIFIER WITHOUT THE FEEDBACK RESISTOR [J].
BERTUCCIO, G ;
REHAK, P ;
XI, DM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :71-76
[2]   SPECTROSCOPY CHARGE AMPLIFIER FOR DETECTORS WITH INTEGRATED FRONT-END FET [J].
BERTUCCIO, G ;
FASOLI, L ;
FIORINI, C ;
SAMPIETRO, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1399-1405
[3]   1ST RESULTS WITH THE PN-CCD DETECTOR SYSTEM FOR THE XMM SATELLITE MISSION [J].
BRAUNINGER, H ;
DANNER, R ;
HAUFF, D ;
LECHNER, P ;
LUTZ, G ;
MEIDINGER, N ;
PINOTTI, E ;
REPPIN, C ;
STRUDER, L ;
TRUMPER, J ;
KENDZIORRA, E ;
KRAMER, J ;
MOHAN, M ;
STAUBERT, R ;
FINDEIS, N ;
HOLL, P ;
KEMMER, J ;
VONZANTHIER, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :129-135
[4]   MINIMUM NOISE PRE-AMPLIFIER FOR FAST IONIZATION CHAMBERS [J].
COTTINI, C ;
GATTI, E ;
GIANNELLI, G ;
ROZZI, G .
NUOVO CIMENTO, 1956, 3 (02) :473-483
[5]  
GATTI E, 1986, NUOVO CIMENTO, V9, P92
[6]  
HOLLAND A, 1991, SP356 ESA
[7]  
JANESICK JR, 1989, ASTRONOMICAL SOC PAC, V6
[8]   PULSED FEEDBACK TECHNIQUES FOR SEMICONDUCTOR DETECTOR RADIATION SPECTROMETERS [J].
LANDIS, DA ;
GOULDING, FS ;
PEHL, RH ;
WALTON, JT .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1971, NS18 (01) :115-&
[9]  
LECHNER P, 1995, P 7 EUR S SEM DET
[10]  
MANFREDI PF, 1993, MATER RES SOC SYMP P, V302, P213, DOI 10.1557/PROC-302-213