SPECTROSCOPY CHARGE AMPLIFIER FOR DETECTORS WITH INTEGRATED FRONT-END FET

被引:19
作者
BERTUCCIO, G
FASOLI, L
FIORINI, C
SAMPIETRO, M
机构
[1] Dipartimento di Elettronica e Informazione, Politecnico di Milano
关键词
D O I
10.1109/23.467728
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A charge amplifier, especially designed for FET integrated on silicon radiation detectors, is presented. The circuit is based on the forward biased FET amplifier configuration, which does not require the feedback resistor nor additional devices for resetting. The severe constraints on the preamplifier design, imposed by the low transconductance of small size integrated FET's, are analyzed as far as loop-gain, bandwidth, and noise are concerned. A circuit topology which satisfies all the requirements even at relative fast shaping time (1 mu s) is proposed and experimentally tested.
引用
收藏
页码:1399 / 1405
页数:7
相关论文
共 25 条
[1]   A NOVEL CHARGE SENSITIVE PREAMPLIFIER WITHOUT THE FEEDBACK RESISTOR [J].
BERTUCCIO, G ;
REHAK, P ;
XI, DM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :71-76
[2]   ROOM-TEMPERATURE X-RAY SPECTROSCOPY WITH A SILICON DIODE DETECTOR AND AN ULTRA-LOW NOISE PREAMPLIFIER [J].
BERTUCCIO, G ;
PULLIA, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1704-1709
[3]   HIGH-RESOLUTION X-RAY SPECTROSCOPY WITH SILICON DRIFT DETECTORS AND INTEGRATED ELECTRONICS [J].
BERTUCCIO, G ;
SAMPIETRO, M ;
FAZZI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :538-542
[4]  
BERTUCCIO G, 1993, SEMICONDUCTOR ROOM T, P205
[5]   1ST RESULTS WITH THE PN-CCD DETECTOR SYSTEM FOR THE XMM SATELLITE MISSION [J].
BRAUNINGER, H ;
DANNER, R ;
HAUFF, D ;
LECHNER, P ;
LUTZ, G ;
MEIDINGER, N ;
PINOTTI, E ;
REPPIN, C ;
STRUDER, L ;
TRUMPER, J ;
KENDZIORRA, E ;
KRAMER, J ;
MOHAN, M ;
STAUBERT, R ;
FINDEIS, N ;
HOLL, P ;
KEMMER, J ;
VONZANTHIER, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :129-135
[6]   SEMICONDUCTOR DRIFT CHAMBER - AN APPLICATION OF A NOVEL CHARGE TRANSPORT SCHEME [J].
GATTI, E ;
REHAK, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (03) :608-614
[7]   SUBOPTIMAL FILTERING OF 1/F-NOISE IN DETECTOR CHARGE MEASUREMENTS [J].
GATTI, E ;
MANFREDI, PF ;
SAMPIETRO, M ;
SPEZIALI, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (03) :467-478
[8]  
GATTI E, 1986, NUOVO CIMENTO, V9, P92
[9]   AN OPTO-ELECTRONIC FEEDBACK PREAMPLIFIER FOR HIGH-RESOLUTION NUCLEAR SPECTROSCOPY [J].
GOULDING, FS ;
WALTON, J ;
MALONE, DF .
NUCLEAR INSTRUMENTS & METHODS, 1969, 71 (03) :273-&
[10]   LOW-FREQUENCY NOISE IN MODERN BIPOLAR-TRANSISTORS - IMPACT OF INTRINSIC TRANSISTOR AND PARASITIC SERIES RESISTANCES [J].
KLEINPENNING, TGM .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1994, 41 (11) :1981-1991