Finite element analysis of covered microstents

被引:40
作者
Gu, LX
Santra, S
Mericle, RA
Kumar, AV
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Neurol Surg, Gainesville, FL 32610 USA
关键词
covered stent; finite element analysis; simulation; silicone; aneurysm; arteriovenous fistula;
D O I
10.1016/j.jbiomech.2004.06.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Currently available neuroendovascular devices are inadequate for effective treatment of many wide-necked or fusiform intracranial aneurysms and intracranial carotid-cavernous fistulae (CCF). Placing a covered microstent across the intracranial aneurysm neck and CCF rent could restore normal vessel morphology by preventing blood flow into the aneurysm lumen or CCF rent. To fabricate covered microstents, our research group has developed highly flexible ultra thin (similar to 150 mu m) silicone coverings and elastomerically captured them onto commercially available metal stents without stitching. Preliminary in vivo studies were conducted by placing these covered microstents in the common carotid artery of rabbits. The feasibility of using covered stents was demonstrated. However, the cover affected the deployment pressure and the stents failed occasionally during deployment due to tearing of the cover. Appropriate modeling of covered stents will assist in designing suitable coverings, and help to reduce the failure rate of covered microstents. The purpose of this study is to use the finite element method to determine the mechanical properties of the covered microstent and investigate the effects of the covering on the mechanical behavior of the covered microstent. Variations in the mechanical properties of the: covered microstent such as deployment pressure, elastic recoil and longitudinal shortening due to change in thickness and material properties of the cover have been investigated. This work is also important for custom design of covered microstents such as adding cutout holes to save adjacent perforating arteries. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1221 / 1227
页数:7
相关论文
共 17 条
[1]  
*ABAQUS, 2002, 63 1 DOC 2002
[2]  
AURICCHIO F, 2000, FINITE ELEMENT ANAL, P1
[3]  
BRAUN IF, 1985, AM J NEURORADIOL, V6, P953
[4]  
DEBRUN G, 1979, SPECIAL THERAPEUTIC, P228
[5]   Mechanical properties of coronary stents determined by using finite element analysis [J].
Etave, F ;
Finet, G ;
Boivin, M ;
Boyer, JC ;
Rioufol, G ;
Thollet, G .
JOURNAL OF BIOMECHANICS, 2001, 34 (08) :1065-1075
[6]   Bypass-surgery and coil-embolisation in the treatment of cerebral giant aneurysms [J].
Ewald, C ;
Kühne, D ;
Hassler, WE .
ACTA NEUROCHIRURGICA, 2000, 142 (07) :731-737
[7]   Evaluation of silicone as an endovascular stent membrane: In vivo canine studies [J].
Fontaine, AB ;
Borsa, JJ ;
Hoffer, E ;
Bloch, R ;
So, C .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 24 (05) :324-328
[8]  
Geremia G, 1997, AM J NEURORADIOL, V18, P271
[9]   REOPERATIVE MANAGEMENT OF INTRACRANIAL ANEURYSMS [J].
GIANNOTTA, SL ;
LITOFSKY, NS .
JOURNAL OF NEUROSURGERY, 1995, 83 (03) :387-393
[10]   Treatment of unruptured cerebral aneurysms in California [J].
Johnston, SC ;
Zhao, SJ ;
Dudley, RA ;
Berman, MF ;
Gress, DR .
STROKE, 2001, 32 (03) :597-603