Highly sensitive voltammetric sensor based on catechol-derivative-multiwall carbon nanotubes for the catalytic determination of captopril in patient human urine samples

被引:131
作者
Ensafi, A. A. [1 ]
Karimi-Maleh, H. [1 ]
Mallakpour, S. [1 ]
Rezaei, B. [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
Captopril; Carbon nanotubes paste electrode; N-(3,4-dihydroxyphenethyl)-3,5-dinitrobenzamide; Electrocatalytic method; Voltammetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; ADSORPTIVE STRIPPING VOLTAMMETRY; ANGIOTENSIN-CONVERTING ENZYME; SEQUENTIAL INJECTION-ANALYSIS; SOLID-PHASE EXTRACTION; CAPILLARY-ELECTROPHORESIS; SPECTROPHOTOMETRIC DETERMINATION; ELECTROCHEMICAL DETECTION; BIOLOGICAL SAMPLES; COMPLEX-FORMATION;
D O I
10.1016/j.colsurfb.2011.06.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new catechol-derivative compound, N-(3,4-dihydroxyphenethyl)-3,5-dinitrobenzamide, was synthesized and used to construct a modified-carbon nanotubes paste electrode. The electro-oxidation of captopril at the surface of the modified electrode was studied using cyclic voltammetry, chronoamperometry, and electrochemical impedance spectroscopy. Under the optimized conditions, the differential pulse voltammetric peak current of captopril increased linearly with captopril concentration in the ranges of 6.4 x 10(-8) to 3.2 x 10(-48) mol L-1. The detection limit was 3.4 x 10(-8) mol L-1 captopril. The diffusion coefficient and kinetic parameters (such as electron transfer coefficient and the heterogeneous rate constant) for captopril oxidation were also determined. The RSD% for 0.5 and 10.0 mu mol L-1 captopril were 2.1% and 1.6%, respectively. The proposed sensor was successfully applied for the determination of captopril in human patient urine and tablet samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:480 / 488
页数:9
相关论文
共 58 条
[1]  
Al-Ghannam SM, 2002, FARMACO, V57, P625
[2]  
Amini M, 1999, Pharm Acta Helv, V73, P303, DOI 10.1016/S0031-6865(99)00007-2
[3]   Determination of captopril in biological samples by highperformance liquid chromatography with ThioGloTM3 derivatization [J].
Aykin, N ;
Neal, R ;
Yusof, M ;
Ercal, N .
BIOMEDICAL CHROMATOGRAPHY, 2001, 15 (07) :427-432
[4]   Determination of captopril in human serum by high performance liquid chromatography using solid-phase extraction [J].
Bahmaei, M ;
Khosravi, A ;
Zamiri, C ;
Massoumi, A ;
Mahmoudian, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (08) :1181-1186
[5]   Application of 2-halopyridinium salts as ultraviolet derivatization reagents and solid-phase extraction for determination of captopril in human plasma by high-performance liquid chromatography [J].
Bald, E ;
Sypniewski, S ;
Drzewoski, J ;
Stepien, M .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 681 (02) :283-289
[6]  
Bard A., 2001, ELECTROCHEMICAL METH
[7]   Nanomolar and Selective Determination of Epinephrine in the Presence of Norepinephrine Using Carbon Paste Electrode Modified with Carbon Nanotubes and Novel 2-(4-Oxo-3-phenyl-3,4-dihydroquinazolinyl)-N′-phenyl-hydrazinecarbothioamide [J].
Beitollahi, Hadi ;
Karimi-Maleh, Hassan ;
Khabazzadeh, Hojatollah .
ANALYTICAL CHEMISTRY, 2008, 80 (24) :9848-9851
[8]   Coumarin-Ser-Asp-Lys-Pro-OH, a fluorescent substrate for determination of angiotensin-converting enzyme activity via high-performance liquid chromatography [J].
Cheviron, N ;
Rousseau-Plasse, A ;
Lenfant, M ;
Adeline, MT ;
Potier, P ;
Thierry, J .
ANALYTICAL BIOCHEMISTRY, 2000, 280 (01) :58-64
[9]   Indirect determination of captopril by AAS [J].
El Reis, MA ;
Abou Attia, FM ;
Kenawy, IMM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (2-3) :249-254
[10]   Utilization of carbon disulphide for the analytical determination of betahistine hydrochloride and captopril in their pharmaceutical preparations [J].
El Walily, AFM ;
Razak, OA ;
Belal, SF ;
Bakry, RS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (02) :439-449