Data-driven optimization and evaluation of 2D EPI and 3D PRESTO for BOLD fMRI at 7 Tesla: I. Focal coverage

被引:19
作者
Barry, Robert L. [1 ,2 ]
Strother, Stephen C. [3 ,4 ]
Gatenby, J. Christopher [1 ,2 ,5 ]
Gore, John C. [1 ,2 ,6 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Radiol & Radiol Sci, Med Ctr, Nashville, TN 37232 USA
[3] Rotman Res Inst, Toronto, ON, Canada
[4] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[5] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[6] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37232 USA
关键词
Functional magnetic resonance imaging (fMRI); Blood oxygenation level dependent (BOLD) contrast; 7; Tesla; PRESTO (Principles of Echo-Shifting with a Train of Observations); Reproducibility; Prediction; FUNCTIONAL MRI; PHYSIOLOGICAL NOISE; BRAIN ACTIVATION; PREPROCESSING CHOICES; NORMAL VOLUNTEER; NEGATIVE BOLD; 1.5; T; FIELD; SIGNAL; STIMULATION;
D O I
10.1016/j.neuroimage.2010.12.086
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI) is commonly performed using 2D single-shot echo-planar imaging (EPI). However, single-shot EPI at 7 Testa (T) often suffers from significant geometric distortions (due to low bandwidth (BW) in the phase-encode (PE) direction) and amplified physiological noise. Recent studies have suggested that 3D multi-shot sequences such as PRESTO may offer comparable BOLD contrast-to-noise ratio with increased volume coverage and decreased geometric distortions. Thus, a four-way group-level comparison was performed between 2D and 3D acquisition sequences at two in-plane resolutions. The quality of fMRI data was evaluated via metrics of prediction and reproducibility using NPAIRS (Non-parametric Prediction, Activation, Influence and Reproducibility re-Sampling). Group activation maps were optimized for each acquisition strategy by selecting the number of principal components that jointly maximized prediction and reproducibility, and showed good agreement in sensitivity and specificity for positive BOLD changes. High-resolution EPI exhibited the highest z-scores of the four acquisition sequences; however, it suffered from the lowest BW in the PE direction (resulting in the worst geometric distortions) and limited spatial coverage, and also caused some subject discomfort through peripheral nerve stimulation (PNS). In comparison, PRESTO also had high z-scores (higher than EPI for a matched in-plane resolution), the highest BW in the PE direction (producing images with superior geometric fidelity), the potential for whole-brain coverage, and no reported PNS. This study provides evidence to support the use of 3D multi-shot acquisition sequences in lieu of single-shot EPI for ultra high field BOLD fMRI at 7 T. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:1034 / 1043
页数:10
相关论文
共 70 条
[51]   ECHO-VOLUME IMAGING [J].
SONG, AW ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) :668-671
[52]   Optimizing the fMRI data-processing pipeline using prediction and reproducibility performance metrics: I. A preliminary group analysis [J].
Strother, S ;
La Conte, S ;
Hansen, LK ;
Anderson, J ;
Zhang, J ;
Pulapura, S ;
Rottenberg, D .
NEUROIMAGE, 2004, 23 :S196-S207
[53]   Evaluating fMRI preprocessing pipelines - Review of preprocessing steps for BOLD fMRI [J].
Strother, SC .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2006, 25 (02) :27-41
[54]   The NPAIRS Computational Statistics Framework for Data Analysis in Neuroimaging [J].
Strother, Stephen ;
Oder, Anita ;
Spring, Robyn ;
Grady, Cheryl .
COMPSTAT'2010: 19TH INTERNATIONAL CONFERENCE ON COMPUTATIONAL STATISTICS, 2010, :111-120
[55]   The quantitative evaluation of functional neuroimaging experiments: The NPAIRS data analysis framework [J].
Strothert, SC ;
Anderson, J ;
Hansen, LK ;
Kjems, U ;
Kustra, R ;
Sidtis, J ;
Frutiger, S ;
Muley, S ;
LaConte, S ;
Rottenberg, D .
NEUROIMAGE, 2002, 15 (04) :747-771
[56]   Noise reduction in BOLD-based fMRI using component analysis [J].
Thomas, CG ;
Harshman, RA ;
Menon, RS .
NEUROIMAGE, 2002, 17 (03) :1521-1537
[57]   The representation of the ipsilateral visual field in human cerebral cortex [J].
Tootell, RBH ;
Mendola, JD ;
Hadjikhani, NK ;
Liu, AK ;
Dale, AM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (03) :818-824
[58]   Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters [J].
Triantafyllou, C ;
Hoge, RD ;
Krueger, G ;
Wiggins, CJ ;
Potthast, A ;
Wiggins, GC ;
Wald, LL .
NEUROIMAGE, 2005, 26 (01) :243-250
[59]   Effect of spatial smoothing on physiological noise in high-resolution fMRI [J].
Triantafyllou, Christina ;
Hoge, Richard D. ;
Wald, Lawrence L. .
NEUROIMAGE, 2006, 32 (02) :551-557
[60]  
van der Meulen P, 1985, Magn Reson Imaging, V3, P297, DOI 10.1016/0730-725X(85)90362-5