Reconstruction of a 4-cm human median nerve gap by including an autogenous nerve slice in a bioabsorbable nerve conduit: Case report

被引:32
作者
Hung, Virginia
Dellon, A. Lee
机构
[1] Dellon Inst Peripheral Nerve Surg, Baltimore, MD USA
[2] Johns Hopkins Univ, Baltimore, MD USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2008年 / 33A卷 / 03期
关键词
conduit; nerve; nerve growth factor; Schwann cell;
D O I
10.1016/j.jhsa.2007.12.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Nerve gaps up to 3 cm in length can be reconstructed in the human with a bioabsorbable nerve conduit; however, nerve gaps greater than 3 cm have not been reconstructible in animal models unless a neurotrophic factor, like cultured Schwann cells, was added to the nerve conduit. It is the purpose of this article to present the result of human nerve regeneration across a 4-cm nerve gap in the median nerve at the wrist when a slice of autogenous normal nerve was placed into the middle of a bioabsorbable nerve conduit.m
引用
收藏
页码:313 / 315
页数:3
相关论文
共 9 条
[1]   AN ALTERNATIVE TO THE CLASSICAL NERVE GRAFT FOR THE MANAGEMENT OF THE SHORT NERVE GAP [J].
DELLON, AL ;
MACKINNON, SE .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1988, 82 (05) :849-856
[2]   Reconstruction of the human median nerve in the forearm with the neurotube™ [J].
Donoghoe, Nicholas ;
Rosson, Gedge D. ;
Dellon, A. Lee .
MICROSURGERY, 2007, 27 (07) :595-600
[3]   Enhancing nerve regeneration across a silicone tube conduit by using interposed short-segment nerve grafts [J].
Francel, PC ;
Francel, TJ ;
Mackinnon, SE ;
Hertl, C .
JOURNAL OF NEUROSURGERY, 1997, 87 (06) :887-892
[5]   CLINICAL NERVE RECONSTRUCTION WITH A BIOABSORBABLE POLYGLYCOLIC ACID TUBE [J].
MACKINNON, SE ;
DELLON, AL .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 85 (03) :419-424
[6]   Composite PHB-GGF conduit for long nerve gap repair: A long-term evaluation [J].
Mohanna, PN ;
Terenghi, G ;
Wiberg, M .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2005, 39 (03) :129-137
[7]   Determining the maximal length of a vein conduit used as an interposition graft for nerve regeneration [J].
Strauch, B ;
Ferder, M ;
LovelleAllen, S ;
Moore, K ;
Kim, DJ ;
Llena, J .
JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 1996, 12 (08) :521-527
[8]   Autologous schwann cells drive regeneration through a 6-cm autogenous venous nerve conduit [J].
Strauch, B ;
Rodriguez, DM ;
Diaz, J ;
Yu, HL ;
Kaplan, G ;
Weinstein, DE .
JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2001, 17 (08) :589-595
[9]   A randomized prospective study of polyglycolic acid conduits for digital nerve reconstruction in humans [J].
Weber, RA ;
Breidenbach, WC ;
Brown, RE ;
Jabaley, ME ;
Mass, DP .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2000, 106 (05) :1036-1045