Incidence and correlates of drug-eluting stent thrombosis in routine clinical practice -: 4-year results from a large 2-institutional cohort study

被引:381
作者
Wenaweser, Peter [1 ]
Daemen, Joost [3 ]
Zwahlen, Marcel [2 ]
van Domburg, Ron [3 ]
Jueni, Peter [2 ]
Vaina, Sophia [3 ]
Hellige, Gerrit [1 ]
Tsuchida, Keiichi [3 ]
Morger, Cyrill [1 ]
Boersma, Eric [3 ]
Kukreja, Neville [3 ]
Meier, Bernhard [1 ]
Serruys, Patrick W. [3 ]
Windecker, Stephan [1 ]
机构
[1] Univ Hosp Bern, Dept Cardiol, CH-3010 Bern, Switzerland
[2] Univ Hosp Bern, Inst Social & Prevent Med, CH-3010 Bern, Switzerland
[3] Erasmus MC, Thoraxctr, Dept Intervent Cardiol, Rotterdam, Netherlands
关键词
drug-eluting stent; mortality; stent thrombosis;
D O I
10.1016/j.jacc.2008.07.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We sought to determine the risk of late stent thrombosis (ST) during long-term follow-up beyond 3 years, searched for predictors, and assessed the impact of ST on overall mortality. Background Late ST was reported to occur at an annual rate of 0.6% up to 3 years after drug-eluting stent (DES) implantation. Methods A total of 8,146 patients underwent percutaneous coronary intervention with a sirolimus-eluting stent (SES) (n = 3,823) or paclitaxel-eluting stent (PES) (n = 4,323) and were followed up to 4 years after stent implantation. Dual antiplatelet treatment was prescribed for 6 to 12 months. Results Definite ST occurred in 192 of 8,146 patients with an incidence density of 1.0/100 patient-years and a cumulative incidence of 3.3% at 4 years. The hazard of ST continued at a steady rate of 0.53% (95% confidence interval [CI]: 0.44 to 0.64) between 30 days and 4 years. Diabetes was an independent predictor of early ST (hazard ratio [HR]: 1.96; 95% CI: 1.18 to 3.28), and acute coronary syndrome (HR: 2.21; 95% CI: 1.39 to 3.51), younger age (HR: 0.97; 95% CI: 0.95 to 0.99), and use of PES (HR: 1.67; 95% CI: 1.08 to 2.56) were independent predictors of late ST. Rates of death and myocardial infarction at 4 years were 10.6% and 4.6%, respectively. Conclusions Late ST occurs steadily at an annual rate of 0.4% to 0.6% for up to 4 years. Diabetes is an independent predictor of early ST, whereas acute coronary syndrome, younger age, and PES implantation are associated with late ST.
引用
收藏
页码:1134 / 1140
页数:7
相关论文
共 34 条
[1]   Incidence and predictors of drug-eluting stent thrombosis during and after discontinuation of thienopyridine treatment [J].
Airoldi, Flavio ;
Colombo, Antonio ;
Morici, Nuccia ;
Latib, Azeem ;
Cosgrave, John ;
Buellesfeld, Lutz ;
Bonizzoni, Erminio ;
Carlino, Mauro ;
Gerckens, Ulrich ;
Godino, Cosmo ;
Melzi, Gloria ;
Michev, Iassen ;
Montorfano, Matteo ;
Sangiorgi, Giuseppe Massimo ;
Qasim, Asif ;
Chieffo, Alaide ;
Briguori, Carlo ;
Grube, Eberhard .
CIRCULATION, 2007, 116 (07) :745-754
[2]   Myocardial infarction redefined -: A consensus Document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction [J].
Alpert, JS ;
Antman, E ;
Apple, F ;
Armstrong, PW ;
Bassand, JP ;
de Luna, AB ;
Beller, G ;
Breithardt, G ;
Chaitman, BR ;
Clemmensen, P ;
Falk, E ;
Fishbein, MC ;
Galvani, M ;
Garson, A ;
Grines, C ;
Hamm, C ;
Jaffe, A ;
Katus, H ;
Kjekshus, J ;
Klein, W ;
Klootwijk, P ;
Lenfant, C ;
Levy, D ;
Levy, RI ;
Luepker, R ;
Marcus, F ;
Näslund, U ;
Ohman, M ;
Pahlm, O ;
Poole-Wilson, P ;
Popp, R ;
Alto, P ;
Pyörälä, K ;
Ravkilde, J ;
Rehnquist, N ;
Roberts, W ;
Roberts, R ;
Roelandt, J ;
Rydén, L ;
Sans, S ;
Simoons, ML ;
Thygesen, K ;
Tunstall-Pedoe, H ;
Underwood, R ;
Uretsky, BF ;
Van de Werf, F ;
Voipio-Pulkki, LM ;
Wagner, G ;
Wallentin, L ;
Wijns, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :959-969
[3]   A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents [J].
Babapulle, MN ;
Joseph, L ;
Bélisle, P ;
Brophy, JM ;
Eisenberg, MJ .
LANCET, 2004, 364 (9434) :583-591
[4]   Late thrombosis of drug-eluting stents: A meta-analysis of randomized clinical trials [J].
Bavry, Anthony A. ;
Kumbhani, Dharam J. ;
Helton, Thomas J. ;
Borek, Przemyslaw P. ;
Mood, Girish R. ;
Bhatt, Deepak L. .
AMERICAN JOURNAL OF MEDICINE, 2006, 119 (12) :1056-1061
[5]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[6]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[7]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678
[8]   Clopidogrel use and long-term clinical outcomes after drug-eluting stent implantation [J].
Eisenstein, Eric L. ;
Anstrom, Kevin J. ;
Kong, David F. ;
Shaw, Linda K. ;
Tuttle, Robert H. ;
Mark, Daniel B. ;
Kramer, Judith M. ;
Harrington, Robert A. ;
Matchar, David B. ;
Kandzari, David E. ;
Peterson, Eric D. ;
Schulman, Kevin A. ;
Califf, Robert M. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 297 (02) :159-168
[9]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[10]   Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation [J].
Hofma, SH ;
van der Giessen, WJ ;
van Dalen, BM ;
Lemos, PA ;
McFadden, EP ;
Sianos, G ;
Ligthart, JMR ;
van Essen, D ;
de Feyter, PJ ;
Serruys, PW .