FAIR true-FISP perfusion imaging of the kidneys

被引:162
作者
Martirosian, P
Klose, U
Mader, I
Schick, F
机构
[1] Univ Tubingen, Dept Diagnost Radiol, Sect Expt Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Sect Expt MR CNS, Dept Neuroradiol, Tubingen, Germany
关键词
FAIR techniques; True-FISP; perfusion weighted imaging; spin labeling; magnetic susceptibility artifacts;
D O I
10.1002/mrm.10709
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Most arterial spin labeling (ASL) techniques apply echoplanar imaging (EPI) because this strategy provides relatively high SNR in short measuring times. Unfortunately, those techniques are very susceptible to static magnetic field inhomogeneities and perfusion signals from organs with fast transverse relaxation might decrease due to the exchange of water molecules in capillaries and organ tissue combined with relatively long echo times of EPI sequences. To overcome these problems a novel imaging technique, FAIR True-FISP, was developed. It combines a FAIR (flow-sensitive alternating inversion recovery) perfusion preparation and a true fast imaging with steady precession (True-FISP) data acquisition strategy. True-FISP was chosen since this sequence type does not show the mentioned disadvantages of EPI, but provides a similar SNR per measuring time. An important problem of this approach is that True-FISP sequences usually work in a steady state which is independent of a previous preparation of magnetization. For this reason a sequence structure had to be developed which keeps the advantages of True-FISP and makes the signal intensity sensitive to the FAIR preparation. Breathhold and non-breathhold examinations of kidneys are presented and possible strategies to quantitative flow measurements are reported. It is shown that correction of spatially inhomogeneous receiver coil characteristics is easily feasible and leads to clinically valuable perfusion examinations of kidneys without application of potentially nephrotoxic contrast media. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:353 / 361
页数:9
相关论文
共 30 条
[1]  
Alpert NM, 2002, J NUCL MED, V43, P470
[2]   Assessment of T1 and T*2 effects in vivo and ex vivo using iron oxide nanoparticles in steady state-dependence on blood volume and water exchange [J].
Bjornerud, A ;
Johansson, LO ;
Briley-Sæbo, K ;
Ahlström, HK .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) :461-471
[3]   Measuring cerebral blood flow using magnetic resonance imaging techniques [J].
Calamante, F ;
Thomas, DL ;
Pell, GS ;
Wiersma, J ;
Turner, R .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1999, 19 (07) :701-735
[4]   STAR-HASTE: Perfusion imaging without magnetic susceptibility artifact [J].
Chen, Q ;
Siewert, B ;
Bly, BM ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :404-408
[5]  
Deimling M., 1994, PROC 2 ANN M SMR SAN, P495
[6]   Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation [J].
Deshpande, VS ;
Chung, YC ;
Zhang, Q ;
Shea, SM ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :151-157
[7]  
Dworkin LD, 1981, KIDNEY
[8]  
EDELMANN RR, 1990, RADIOLOGY, V192, P513
[9]   STEADY-STATE FREE PRECESSION IMAGING IN THE PRESENCE OF MOTION - APPLICATION FOR IMPROVED VISUALIZATION OF THE CEREBROSPINAL-FLUID [J].
HAACKE, EM ;
WIELOPOLSKI, PA ;
TKACH, JA ;
MODIC, MT .
RADIOLOGY, 1990, 175 (02) :545-552
[10]   Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE [J].
Karger, N ;
Biederer, J ;
Lüsse, S ;
Grimm, J ;
Steffens, JC ;
Heller, M ;
Glüer, CC .
MAGNETIC RESONANCE IMAGING, 2000, 18 (06) :641-647