A two year in vivo study of polyvinyl alcohol-hydrogel (PVA-H) artificial meniscus

被引:307
作者
Kobayashi, M
Chang, YS
Oka, M
机构
[1] Osaka Med Coll, Dept Orthoped Surg, Takatsuki, Osaka 5698688, Japan
[2] Kyoto Univ, Inst Frontier Med Sci, Dept Tissue Regenerat, Kyoto, Japan
关键词
polyvinylalcohol; arthritis; knee replacement; in vivo test;
D O I
10.1016/j.biomaterials.2004.08.028
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
For the recognized importance of knee meniscus function, the treatment of meniscus injury has been changing from resection to repair. However, depending on the type of injury, meniscectomy sometimes cannot be avoided. In such a case, it is important to anticipate the future problem of degenerative change or osteoarthrosis in the knee joint. In consideration of the prognosis and circumstances in such patients, we have developed an artificial meniscus using polyvinyl alcohol-hydrogel (PVA-H) for salvage. We have already reported the results up to 1 year after animal operation. The present study investigated the results in postoperative 2.0 years to assess further the use of artificial meniscus. In the results, the articular cartilage state of knee joint implanted PVA-H meniscus was good even after 2 years, while Osteoarthrosis (OA) change progressed in meniscectomy knee joint. In addition, neither wear, dislocation nor breakage of PVA-H was observed. These results proved that an artificial meniscus using PVA-H can compensate for meniscal function and might be clinically applicable. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3243 / 3248
页数:6
相关论文
共 29 条
[1]
ARNOCZKY SP, 1990, CLIN ORTHOP RELAT R, P121
[2]
PROTEIN PERMEATION THROUGH POLY(VINYL ALCOHOL) HYDROGEL MEMBRANES [J].
BURCZAK, K ;
FUJISATO, T ;
HATADA, M ;
IKADA, Y .
BIOMATERIALS, 1994, 15 (03) :231-238
[3]
Chang YS, 1997, J BIOMED MATER RES, V37, P51, DOI 10.1002/(SICI)1097-4636(199710)37:1<51::AID-JBM7>3.3.CO
[4]
2-Y
[5]
Meniscal tissue regeneration in porous 50/50 copoly(L-lactide/epsilon-caprolactone) implants [J].
deGroot, JH ;
Zijlstra, FM ;
Kuipers, HW ;
Pennings, AJ ;
Klompmaker, J ;
Veth, RPH ;
Jansen, HWB .
BIOMATERIALS, 1997, 18 (08) :613-622
[6]
KNEE JOINT CHANGES AFTER MENISCECTOMY [J].
FAIRBANK, TJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1948, 30 (04) :664-670
[7]
FITHIAN DC, 1990, CLIN ORTHOP RELAT R, P19
[8]
Meniscal replacement using a porous polymer prosthesis: A preliminary study in the dog [J].
Klompmaker, J ;
Veth, RPH ;
Jansen, HWB ;
Nielsen, HKL ;
deGroot, JH ;
Pennings, AJ .
BIOMATERIALS, 1996, 17 (12) :1169-1175
[9]
POROUS POLYMER IMPLANT FOR REPAIR OF MENISCAL LESIONS - A PRELIMINARY-STUDY IN DOGS [J].
KLOMPMAKER, J ;
JANSEN, HWB ;
VETH, RPH ;
DEGROOT, JH ;
NIJENHUIS, AJ ;
PENNINGS, AJ .
BIOMATERIALS, 1991, 12 (09) :810-816
[10]
Preliminary study of polyvinyl alcohol-hydrogel (PVA-H) artificial meniscus [J].
Kobayashi, M ;
Toguchida, J ;
Oka, M .
BIOMATERIALS, 2003, 24 (04) :639-647