Morphologic and mechanical characteristics of engineered bovine arteries

被引:192
作者
Niklason, LE
Abbott, W
Gao, JM
Klagges, B
Hirschi, KK
Ulubayram, K
Conroy, N
Jones, R
机构
[1] Duke Univ, Dept Anesthesiol, Durham, NC 27708 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[3] Massachusetts Gen Hosp, Dept Surg, Boston, MA 02114 USA
[4] Massachusetts Gen Hosp, Dept Anesthesiol, Cambridge, MA USA
[5] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[6] SUNY Buffalo, Sch Med & Biomed Sci, Houston, TX USA
[7] Hacettepe Univ, Dept Pharm, TR-06100 Ankara, Turkey
[8] Georgetown Univ, Washington, DC USA
[9] Johns Hopkins Univ, Sch Med, Baltimore, MD USA
[10] MIT, Dept Biol, Cambridge, MA 02139 USA
[11] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
关键词
D O I
10.1067/mva.2001.111747
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The ideal small-caliber arterial graft remains elusive despite several decades of intense research. A novel approach to the development of small-caliber arterial prostheses with a biomimetic system for in vitro vessel culture has recently been described. In this study we examined the effects of culture time and tissue culture scaffolding on engineered vessel morphology and function and found that these parameters greatly influence the function of engineered vessels. Methods: This report describes the effects of culture time and scaffold type on vessel morphology cellular differentiation, and vessel mechanical characteristics. Engineered vessels were cultured from bovine aortic smooth muscle cells (SMCs) and endothelial cells that were seeded onto biodegradable polymer scaffolds and cultured under physiologically pulsatile conditions. Engineered vessels were subjected to histologic, ultrastructural, immunocytochemical, and mechanical analyses. Results: Vessel morphology and mechanical characteristics improved as time in culture increased to 8 weeks. SMCs in the engineered vessel wall were organized into a highly lamellar structure, with cells separated by alternating layers of collagen fibrils. Polymer scaffold remnants were present in vessels cultured for 8 weeks, and SMCs that were in proximity to polymer renmants exhibited a dedifferentiated phenotype. Conclusions: These findings aid in the systematic understandings of the effects of in vitro parameters on engineered vessels and will be useful for the translation of vessel culture techniques to human cells for the development of autologous human vascular grafts.
引用
收藏
页码:628 / 638
页数:11
相关论文
共 27 条
[1]   ASSESSMENT OF ELASTIN AND COLLAGEN CONTRIBUTION TO AORTIC ELASTICITY IN CONSCIOUS DOGS [J].
ARMENTANO, RL ;
LEVENSON, J ;
BARRA, JG ;
FISCHER, EIC ;
BREITBART, GJ ;
PICHEL, RH ;
SIMON, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1991, 260 (06) :H1870-H1877
[2]   Characteristics of vascular wall cells subjected to dynamic cyclic strain and fluid shear conditions in vitro [J].
Benbrahim, A ;
LItalien, GJ ;
Kwolek, CJ ;
Petersen, MJ ;
Milinazzo, B ;
Gertler, JP ;
Abbott, WM ;
Orkin, RW .
JOURNAL OF SURGICAL RESEARCH, 1996, 65 (02) :119-127
[3]   GROWTH-FACTOR EFFECTS ON CELLS OF THE VASCULAR WALL - A SURVEY [J].
DAMORE, PA ;
SMITH, SR .
GROWTH FACTORS, 1993, 8 (01) :61-75
[4]   BIODEGRADABLE POLYMER SCAFFOLDS FOR TISSUE ENGINEERING [J].
FREED, LE ;
VUNJAKNOVAKOVIC, G ;
BIRON, RJ ;
EAGLES, DB ;
LESNOY, DC ;
BARLOW, SK ;
LANGER, R .
BIO-TECHNOLOGY, 1994, 12 (07) :689-693
[5]  
Gao JM, 1998, J BIOMED MATER RES, V42, P417, DOI 10.1002/(SICI)1097-4636(19981205)42:3<417::AID-JBM11>3.3.CO
[6]  
2-N
[7]   BIODEGRADABLE POLYMERS FOR USE IN SURGERY - POLYGLYCOLIC-POLY(ACTIC ACID) HOMOPOLYMERS AND COPOLYMERS .1. [J].
GILDING, DK ;
REED, AM .
POLYMER, 1979, 20 (12) :1459-1464
[8]  
GILDING DK, 1981, FUNDAMENTAL ASPECTS, P43
[9]  
Greisler H, 1988, ASAIO Trans, V34, P1051
[10]   Biointeractive polymers and tissue engineered blood vessels [J].
Greisler, HP ;
Gosselin, C ;
Ren, DW ;
Kang, SS ;
Kim, DU .
BIOMATERIALS, 1996, 17 (03) :329-336