An ion funnel interface for improved ion focusing and sensitivity using electrospray ionization mass spectrometry

被引:228
作者
Shaffer, SA [1 ]
Prior, DC [1 ]
Anderson, GA [1 ]
Udseth, HR [1 ]
Smith, RD [1 ]
机构
[1] Pacific NW Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1021/ac9802170
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To improve upon the already impressive sensitivity achievable with electrospray ionization sources, a novel electrohydrodynamic ion funnel interface has been developed and implemented with a triple-quadrupole mass spectrometer. The ion funnel interface effectively consists of a series of ring electrodes of increasingly small internal diameters to which rf and de electric potentials are coapplied. In the 1-10-Torr pressure range, the electric fields cause the collisionally damped ions to be more effectively focused and transmitted as a collimated ion beam. This paper describes the ion funnel design and presents an evaluation of its performance using a triple-quadrupole mass spectrometer. Ion transmission and m/z discriminating parameters (resulting in both effective low- and high-m/z cutoffs) are presented based upon both ion current measurements and mass spectra. Electrospray ionization mass spectra of selected protein solutions demonstrated well over 1 order of magnitude increase in signal relative to that of the instrument operated in its standard (inlet capillary-skimmer) configuration under similar conditions. The present results suggest that it will be feasible to realize close to 100% ion transmission efficiency for analytically relevant ions through the electrospray ionization interface and into the mass analyzer.
引用
收藏
页码:4111 / 4119
页数:9
相关论文
共 29 条
[1]   MICRO-ELECTROSPRAY - ZEPTOMOLE-ATTOMOLE PER MICROLITER SENSITIVITY FOR PEPTIDES [J].
ANDREN, PE ;
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (09) :867-869
[2]  
Bahr R., 1969, VERH DTSCH PHYS GES, V4, P343
[3]   SPACE-CHARGE-DOMINATED MASS-SPECTROMETRY ION SOURCES - MODELING AND SENSITIVITY [J].
BUSMAN, M ;
SUNNER, J ;
VOGEL, CR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (01) :1-10
[4]   Collision cross sections of myoglobin and cytochrome c ions with Ne, Ar, and Kr [J].
Chen, YL ;
Collings, BA ;
Douglas, DJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (07) :681-687
[6]  
DAWSON PH, 1976, QUADRUOPOLE MASS SPE
[7]  
Dodonov A, 1997, RAPID COMMUN MASS SP, V11, P1649, DOI 10.1002/(SICI)1097-0231(19971015)11:15<1649::AID-RCM67>3.0.CO
[8]  
2-T
[9]   COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :398-408
[10]   Applications of collision dynamics in quadrupole mass spectrometry [J].
Douglas, DJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (02) :101-113