Coupling of monolithic columns with sequential injection technique -: A new separation approach in flow methods

被引:46
作者
Huclová, J [1 ]
Satínsky, D [1 ]
Karlícek, R [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Res Ctr LN00B125, Dept Analyt Chem, Hradec Kralove 50005, Czech Republic
关键词
sequential injection chromatography; sequential injection analysis; monolithic column; salicylic acid; methylsalicylate;
D O I
10.1016/S0003-2670(03)00902-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sequential injection chromatography (SIC) system was created by incorporating a monolithic chromatography column into a standard sequential injection analysis (SIA) manifold. The system was successfully used for separation of salicylic acid (SA) and its ester methylsalicylate (MS) and for determination of these compounds in a topical pharmaceutical preparation. The separation was performed on Chromolith((R)) SpeedROD RP-18e, 50-4.6 mm column (Merck, Germany) placed between the selection valve and the detection cell with acetonitrile-water (35/60 (v/v)), pH 2.5 as the mobile phase. The eluted compounds were detected by diode array Ocean Optics spectrophotometer at 240 nm. Propylparaben (PP) was chosen as a suitable internal standard for quantification of the desired substances. The relation between the absorbance signal and concentration was linear in the range 0.17-43.2 mugml(-1) for SA, 0.24-60.2 mugml(-1) for MS and 0.24-58.8 mugml(-1) for PP. The detection limits were 0.04 mugml(-1) (SA) and 0.15 mugml(-1) (MS), respectively. The recoveries of the determined compounds in the pharmaceutical paste were found above 96%. The values of common chromatographic parameters obtained by the proposed system (resolution, number of theoretical plates and peak asymmetry) are presented. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 21 条
[1]   APPLICATION OF GAS-LIQUID-CHROMATOGRAPHY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY TO ANALYSIS OF TRACE AMOUNTS OF SALICYLIC-ACID, ACETYLSALICYLIC ANHYDRIDE AND ACETYLSALICYLSALICYLIC ACID IN ASPIRIN SAMPLES AND ASPIRIN FORMULATIONS [J].
ALI, SL .
JOURNAL OF CHROMATOGRAPHY, 1976, 126 (NOV3) :651-663
[2]   SilicaROD™ -: A new challenge in fast high-performance liquid chromatography separations [J].
Cabrera, K ;
Wieland, G ;
Lubda, D ;
Nakanishi, K ;
Soga, N ;
Minakuchi, H ;
Unger, KK .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (01) :50-53
[3]   Sequential injection sandwich technique for the simultaneous determination of nitrate and nitrite [J].
Cerdà, A ;
Oms, MT ;
Forteza, R ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 1998, 371 (01) :63-71
[4]   Synchronous fluorimetric determination of salicylic acid and diflunisal in human serum using partial least-squares calibration [J].
delaPena, AM ;
Moreno, MD ;
DuranMeras, I ;
Salinas, F .
TALANTA, 1996, 43 (08) :1349-1356
[5]   HPLC assay of acetylsalicylic acid, paracetamol, caffeine and phenobarbital in tablets [J].
Franeta, JT ;
Agbaba, D ;
Eric, S ;
Pavkov, S ;
Aleksic, M ;
Vladimirov, S .
FARMACO, 2002, 57 (09) :709-713
[6]   COMBINED GAS CHROMATOGRAPHY MASS SPECTROMETRY IN DETERMINATION OF URINARY ANTHRANILIC ACID [J].
HIRANO, K ;
OHNO, T ;
NARUSE, M ;
KAWAI, S .
JOURNAL OF CHROMATOGRAPHY, 1972, 70 (01) :53-&
[7]   Determination of salbutamol using on-line solid-phase extraction and sequential injection analysis.: Comparison of chemiluminescence and fluorescence detection [J].
Huclová, J ;
Satínsky, D ;
Sklenárová, H ;
Karlícek, R .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (04) :448-454
[8]   Performance of different preconcentration columns used in sequential injection analysis and inductively coupled plasma-mass spectrometry for multielemental determination in seawater [J].
Jiménez, MS ;
Velarte, R ;
Castillo, JR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (03) :391-402
[9]   Simultaneous quantitative analysis of methyl salicylate, ethyl salicylate and salicylic acid from biological fluids using gas chromatography mass spectrometry [J].
Kakkar, T ;
Mayersohn, M .
JOURNAL OF CHROMATOGRAPHY B, 1998, 718 (01) :69-75
[10]   AUTOMATED FLOW-INJECTION DETERMINATION OF SALICYLATES USING TRINDER REACTION FOR CLINICAL ANALYSIS, ASSAYS AND DISSOLUTION STUDIES OF FORMULATIONS [J].
KOUPPARIS, MA ;
ANAGNOSTOPOULOU, PI .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1988, 6 (01) :35-46