Determination of acetylsalicylic acid in tablets with salicylate ion selective electrode in a batch injection analysis system

被引:10
作者
Fernandes, JCB [1 ]
Garcia, CB
Grandin, LA
Neto, GD
Godinho, OES
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13081970 Campinas, SP, Brazil
[2] Univ Fed Maranhao, Ctr Technol, Dept Quim, BR-65080040 Sao Luis, MA, Brazil
关键词
potentiometry; ion selective electrode; batch injection analysis; acetylsalicylic acid;
D O I
10.1590/S0103-50531998000300008
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The feasibility of the use of a Batch Injection Analysis (BIA) system for potentiometric determination of acetylsalicylic acid in tablets, with a membrane ion selective electrode, was investigated. There is no significant difference between the results obtained by the proposed method(12) at the 95% confidence level. and those obtained by the Standard British Pharmacopaeia method Values of 4% and 2.5% for R.S.D. were obtained by the application of the BIA-potentiometric method and for the injections respectively. About 90 determinations per hour can be performed with the proposed BIA potentiometric method.
引用
收藏
页码:249 / 251
页数:3
相关论文
共 13 条
[1]   DETERMINATION OF SALICYLIC-ACID AND BENZOIC-ACID IN PHARMACEUTICAL FORMULATIONS BY SPECTROFLUORIMETRY [J].
ADAMS, S ;
MILLER, JHM .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1978, 30 (02) :81-83
[2]   BATCH INJECTION-ANALYSIS WITH THE ROTATING-DISK ELECTRODE [J].
CHEN, LA ;
WANG, J ;
ANGNES, L .
ELECTROANALYSIS, 1991, 3 (08) :773-776
[3]  
CHRISTIAN GD, 1994, ANAL CHEM, P39
[4]   DETERMINATION OF SALICYLIC-ACID IN PHARMACEUTICAL FORMULATIONS AND FOODS BY DIFFERENTIAL-PULSE VOLTAMMETRY USING A GLASSY-CARBON ELECTRODE [J].
FUNG, YS ;
LUK, SF .
ANALYST, 1989, 114 (08) :943-945
[5]   A RAPID METHOD FOR ESTIMATION OF SALICYLATE IN SERUM [J].
FURMAN, M ;
FINBERG, L .
JOURNAL OF PEDIATRICS, 1967, 70 (02) :287-+
[6]   LIQUID MEMBRANE-ELECTRODE FOR SELECTIVE DETERMINATION OF SALICYLATE IN PHARMACEUTICAL PREPARATIONS [J].
HASSAN, SSM ;
HAMADA, MA .
ANALYST, 1988, 113 (11) :1709-1713
[7]  
ROVER L, IN PRESS ANAL CHIM A
[8]   IMPROVED GAS-LIQUID CHROMATOGRAPHIC-FLAME IONIZATION DETECTION ASSAY OF ACETYLSALICYLIC AND SALICYLIC ACIDS [J].
TAM, YK ;
AU, DSL ;
ABBOTT, FS .
JOURNAL OF CHROMATOGRAPHY, 1979, 174 (01) :239-244
[9]   RAPID DETERMINATION OF SALICYLATE IN BIOLOGICAL FLUIDS [J].
TRINDER, P .
BIOCHEMICAL JOURNAL, 1954, 57 (02) :301-303
[10]   BATCH INJECTION-ANALYSIS [J].
WANG, J ;
TAHA, Z .