Curved-slab maximum intensity projection: Method and evaluation

被引:16
作者
Raman, R [1 ]
Napel, S [1 ]
Rubin, GD [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
关键词
computed tomography (CT); angiography; maximum intensity projection;
D O I
10.1148/radiol.2291020370
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors developed and evaluated a method to produce curved-slab maximum intensity projections (MIPs) through blood vessels that semiautomatically excludes soft tissue and bone. Results obtained with the algorithm were compared with those obtained with rectangular-slab MIPs by using computed tomographic (CT) data from four patients with abdominal aortic aneurysms. Curved-slab MIPs exhibited increased mean vessel-to-perivascular tissue contrast of 55.1 HU (36%), allowed a 10% increase in contrast-to-noise ratio, and decreased apparent vessel narrowing by 0.12-1.09 mm, without increasing processing time. Curved-slab MIPs may also include multiple vessels in a single image, thereby improving interpretation efficiency by reducing the number of MIPs required in these patients from eight to three. (C) RSNA, 2003.
引用
收藏
页码:255 / 260
页数:6
相关论文
共 15 条
[1]   ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS [J].
ANDERSON, CM ;
SALONER, D ;
TSURUDA, JS ;
SHAPEERO, LG ;
LEE, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :623-629
[2]   CONTRAST-TO-NOISE RATIOS IN MAXIMUM INTENSITY PROJECTION IMAGES [J].
BROWN, DG ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :130-137
[3]   PROSPECTIVE EVALUATION OF EXTRACRANIAL CAROTID STENOSIS - NIR ANGIOGRAPHY WITH MAXIMUM-INTENSITY PROJECTIONS AND MULTIPLANAR REFORMATION COMPARED WITH CONVENTIONAL ANGIOGRAPHY [J].
DEMARCO, JK ;
NESBIT, GM ;
WESBEY, GE ;
RICHARDSON, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) :1205-1212
[4]   Blurring of vessels in spiral CT angiography: Effects of collimation width, pitch, viewing plane, and windowing in maximum intensity projection [J].
Diederichs, CG ;
Keating, DP ;
Glatting, G ;
Oestmann, JW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (06) :965-974
[5]   Increasing spiral CT benefits with postprocessing applications [J].
Kirchgeorg, MA ;
Prokop, M .
EUROPEAN JOURNAL OF RADIOLOGY, 1998, 28 (01) :39-54
[6]   Technical aspects of CT angiography [J].
Kuszyk, BS ;
Fishman, EK .
SEMINARS IN ULTRASOUND CT AND MRI, 1998, 19 (05) :383-393
[7]   MR ANGIOGRAPHY WITH GRADIENT MOTION REFOCUSING [J].
LAUB, GA ;
KAISER, WA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (03) :377-382
[8]  
Lucas A, 2000, J CARDIOVASC SURG, V41, P73
[9]   CT ANGIOGRAPHY WITH SPIRAL CT AND MAXIMUM INTENSITY PROJECTION [J].
NAPEL, S ;
MARKS, MP ;
RUBIN, GD ;
DAKE, MD ;
MCDONNELL, CH ;
SONG, SM ;
ENZMANN, DR ;
JEFFREY, RB .
RADIOLOGY, 1992, 185 (02) :607-610
[10]   Automated flight path planning for virtual endoscopy [J].
Paik, DS ;
Beaulieu, CF ;
Jeffrey, RB ;
Rubin, GD ;
Napel, S .
MEDICAL PHYSICS, 1998, 25 (05) :629-637