Blurring of vessels in spiral CT angiography: Effects of collimation width, pitch, viewing plane, and windowing in maximum intensity projection

被引:27
作者
Diederichs, CG [1 ]
Keating, DP [1 ]
Glatting, G [1 ]
Oestmann, JW [1 ]
机构
[1] UNIV GOTTINGEN,DEPT RADIOL 1,GOTTINGEN,GERMANY
关键词
computed tomography; instrumentation; spiral; angiography; physics;
D O I
10.1097/00004728-199611000-00018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Our goal was to examine the effects of collimation width (CW), pitch, viewing plane, and windowing on the display of in-plane vessels in maximum intensity projection (MIP). Method: A theoretical concept based on partial volume averaging of vessels was developed to describe the contents of voxels (densities) in MIP and to derive cross-sectional vessel diameters and blurring. To validate the concept and to describe the influence of pitch, a Plexiglas cone submerged in water was scanned with varying CW and pitch. Binary MIP with three representative window levels was chosen so that definitive vessel diameters could be quantitated. Results: The theoretical concept correctly predicted voxel contents and blurring for CW greater than or equal to 3 mm and low pitch. For high pitch, actual blurring was larger; however, for a given table speed, blurring of the cone decreased with pitch while increasing with CW. Overall blurring was most effectively reduced by using a thin CW and the transverse viewing plane. In the transverse viewing plane, the least blurring was found using binary MIP with a low window level. On the contrary, in the longitudinal viewing plane, blurring was minimized using a window level halfway between the density of the cone and that of the surrounding water. Conclusion: For CW greater than or equal to 3 mm, blurring of in-plane vessels can be explained with a simple geometrical concept based on partial volume. For accurate display, the transverse viewing plane should be used, a proper windowing must be chosen, and the CW should be kept below vessel size while raising the pitch to cover a reasonable volume.
引用
收藏
页码:965 / 974
页数:10
相关论文
共 26 条
[1]  
BRINK JA, 1992, RADIOLOGY, V185, P126
[2]   SPIRAL CT - DECREASED SPATIAL-RESOLUTION INVIVO DUE TO BROADENING OF SECTION-SENSITIVITY PROFILE [J].
BRINK, JA ;
HEIKEN, JP ;
BALFE, DM ;
SAGEL, SS ;
DICROCE, J ;
VANNIER, MW .
RADIOLOGY, 1992, 185 (02) :469-474
[3]   TECHNICAL OPTIMIZATION OF SPIRAL CT FOR DEPICTION OF RENAL-ARTERY STENOSIS - IN-VITRO ANALYSIS [J].
BRINK, JA ;
LIM, JT ;
WANG, G ;
HEIKEN, JP ;
DEYOE, LA ;
VANNIER, MW .
RADIOLOGY, 1995, 194 (01) :157-163
[4]  
BRINK JA, 1993, RADIOLOGY, V189, P189
[5]  
CANN CE, 1992, RADIOLOGY, V185, P126
[6]   COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION [J].
CRAWFORD, CR ;
KING, KF .
MEDICAL PHYSICS, 1990, 17 (06) :967-982
[7]   CT ANGIOGRAPHY - APPLICATION TO THE EVALUATION OF CAROTID-ARTERY STENOSIS [J].
DILLON, EH ;
VANLEEUWEN, MS ;
FERNANDEZ, MA ;
EIKELBOOM, BC ;
MALI, WPTM .
RADIOLOGY, 1993, 189 (01) :211-219
[8]   SPIRAL CT ANGIOGRAPHY [J].
DILLON, EH ;
VANLEEUWEN, MS ;
FERNANDEZ, MA ;
MALI, WPTM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) :1273-1278
[9]   HOW TO MEASURE CAROTID STENOSIS [J].
FOX, AJ .
RADIOLOGY, 1993, 186 (02) :316-318
[10]   RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY [J].
GALANSKI, M ;
PROKOP, M ;
CHAVAN, A ;
SCHAEFER, CM ;
JANDELEIT, K ;
NISCHELSKY, JE .
RADIOLOGY, 1993, 189 (01) :185-192