Temperature rise induced by some light emitting diode and quartz-tungsten-halogen curing units

被引:69
作者
Asmussen, E [1 ]
Peutzfeldt, A [1 ]
机构
[1] Univ Copenhagen, Dept Dent Mat, Sch Dent, Fac Hlth Sci, DK-2200 Copenhagen, Denmark
关键词
heat generation; photopolymerization; power density; pulpal damage; resin composite;
D O I
10.1111/j.1600-0722.2004.00181.x
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Because of the risk of thermal damage to the pulp, the temperature rise induced by light-curing units should not be too high. LED (light emitting diode) curing units have the main part of their irradiation in the blue range and have been reported to generate less heat than QTH (quartz-tungsten-halogen) curing units. This study had two aims: first, to measure the temperature rise induced by ten LED and three QTH curing units; and, second, to relate the measured temperature rise to the power density of the curing units. The light-induced temperature rise was measured by means of a thermocouple embedded in a small cylinder of resin composite. The power density was measured by using a dental radiometer. For LED units, the temperature rise increased with increasing power density, in a statistically significant manner. Two of the three QTH curing units investigated resulted in a higher temperature rise than LED curing units of the same power density. Previous findings, that LED curing units induce less temperature rise than QTH units, does not hold true in general.
引用
收藏
页码:96 / 98
页数:3
相关论文
共 16 条
[1]
EXTENT OF POLYMERIZATION OF DENTAL RESINS BY DIFFERENTIAL SCANNING CALORIMETRY [J].
ANTONUCCI, JM ;
TOTH, EE .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (02) :121-125
[2]
BRUNING JL, 1997, COMPUTATIONAL HDB ST, P192
[3]
Effect of light power density variations on bulk curing properties of dental composites [J].
Emami, N ;
Söderholm, KJM ;
Berglund, LA .
JOURNAL OF DENTISTRY, 2003, 31 (03) :189-196
[4]
HALD A, 1952, STATISTICAL THEORY E, P522
[5]
In-vitro pulp chamber temperature rise during composite resin polymerization with various light-curing sources [J].
Hannig, M ;
Bott, B .
DENTAL MATERIALS, 1999, 15 (04) :275-281
[6]
HANSEN EK, 1993, SCAND J DENT RES, V101, P176
[7]
Hofmann N, 2003, AM J DENT, V16, P421
[8]
Effect of irradiation type (LED or QTH) on photo-activated composite shrinkage strain kinetics, temperature rise, and hardness [J].
Hofmann, N ;
Hugo, B ;
Klaiber, B .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2002, 110 (06) :471-479
[9]
Curing efficiency and heat generation of various resin composites cured with high-intensity halogen lights [J].
Kleverlaan, CJ ;
de Gee, AJ .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2004, 112 (01) :84-88
[10]
Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes [J].
Knezevic, A ;
Tarle, Z ;
Meniga, A ;
Sutalo, J ;
Pichler, G ;
Ristic, M .
JOURNAL OF ORAL REHABILITATION, 2001, 28 (06) :586-591