Data analysis for surface plasmon resonance sensors using dynamic baseline algorithm

被引:45
作者
Thirstrup, C [1 ]
Zong, W [1 ]
机构
[1] Vir AS, Vir Biosensor, DK-2630 Taatstrup, Denmark
关键词
surface plasmon; biosensor; data analysis; fitting algorithm;
D O I
10.1016/j.snb.2004.09.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Needs of accurate and robust responses from surface plasmon resonance (SPR) sensor systems put high requirements to the data analysis methods used. The output of an SPR sensor comprises data of reflected light intensity as function of either wavelength or angle of incidence (SPR curve). As reported in the literature, commonly used methods for analysing the SPR curve are polynomial curve fitting methods and the centroid method. These methods have their drawbacks in either being sensitive to correlated noise or drift from the light source, or generating high noise on the SPR response. We propose a modified analysis algorithm, where a baseline for selection of data from the SPR curve is adjusted dynamically according to a pre-defined ratio between the areas of the SPR curve below and above the baseline. It is shown in a mathematical model, numerical simulations as well as in experiments that the proposed dynamic baseline algorithm is insensitive to optical power correlated noise/drift. The algorithm is mathematically simple and it can be readily combined with commonly used data analysis methods. (c) 2004 Published by Elsevier B.V.
引用
收藏
页码:796 / 802
页数:7
相关论文
共 16 条
  • [1] Optimal linear data analysis for surface plasmon resonance biosensors
    Chinowsky, TM
    Jung, LS
    Yee, SS
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) : 89 - 97
  • [2] Surface plasmon resonance sensors: review
    Homola, J
    Yee, SS
    Gauglitz, G
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) : 3 - 15
  • [3] Sensitivity deviation:: instrumental linearity errors that influence concentration analyses and kinetic evaluation of biomolecular interactions
    Johansen, K
    Lundström, I
    Liedberg, B
    [J]. BIOSENSORS & BIOELECTRONICS, 2000, 15 (9-10) : 503 - 509
  • [4] JOHNSTON KS, 1997, ANAL CHEM, V69, P1851
  • [5] Sensitivity and detection limit of concentration and adsorption measurements by laser-induced surface-plasmon resonance
    Kolomenskii, AA
    Gershon, PD
    Schuessler, HA
    [J]. APPLIED OPTICS, 1997, 36 (25): : 6539 - 6547
  • [6] Detection of DNA hybridization using the TISPR-1 surface plasmon resonance biosensor
    Kukanskis, K
    Elkind, J
    Melendez, J
    Murphy, T
    Miller, G
    Garner, H
    [J]. ANALYTICAL BIOCHEMISTRY, 1999, 274 (01) : 7 - 17
  • [7] Asymmetric SPR sensor response curve-fitting equation for the accurate determination of SPR resonance angle
    Kurihara, K
    Nakamura, K
    Suzuki, K
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 86 (01) : 49 - 57
  • [8] A COMPACT SURFACE-PLASMON RESONANCE SENSOR FOR MEASUREMENT OF WATER IN PROCESS
    MATSUBARA, K
    KAWATA, S
    MINAMI, S
    [J]. APPLIED SPECTROSCOPY, 1988, 42 (08) : 1375 - 1379
  • [9] Myszka DG, 1999, J MOL RECOGNIT, V12, P390, DOI 10.1002/(SICI)1099-1352(199911/12)12:6<390::AID-JMR482>3.0.CO
  • [10] 2-8