Prostate cancer detection: Relationship to prostate size

被引:75
作者
Chen, ME
Troncoso, P
Johnston, D
Tang, K
Babaian, RJ
机构
[1] Univ Texas, MD Anderson Cancer Ctr, Dept Urol, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Cancer Ctr, Dept Pathol, Houston, TX 77030 USA
[3] Univ Texas, MD Anderson Cancer Ctr, Dept Biomath, Houston, TX 77030 USA
关键词
D O I
10.1016/S0090-4295(98)00574-3
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives. It has been suggested that the lower detection rate for cancer in large prostates is due to the smaller proportion of tissue sampled. To examine this hypothesis, we evaluated whole-mount radical prostatectomy specimens in which the volume of cancer had been determined. We correlated cancer volume to overall gland volume. In addition, we performed stochastic computer simulations of parasagittal sextant biopsies on the same group of radical prostatectomy specimens. We correlated the likelihood of a positive cancer biopsy simulation with tumor volume and gland size. Methods. Six hundred seven tumor foci from 180 serially sectioned whole-mount prostatectomy specimens were mapped and digitized. Tumor volume was calculated by a step-section planimetry algorithm. Before sectioning, each gland was weighed. Systematic parasagittal sextant biopsies were computer simulated for each case. For each prostate, 40 simulations were performed, with random variations in biopsy location programmed for each run. Overall cancer detection by biopsy was considered positive if 90% of the 40 simulation runs were positive for cancer. Chi-square tests were used to evaluate statistical significance. Results. Small-volume cancers (0.5 cc or less) were twice as frequent in large glands greater than 50 g (P = 0.03). These small-volume tumors comprised 33% (13 of 40) of cancers in prostates greater than 50 g, 16% (5 of 31) in glands less than 30 g, and 14% (15 of 109) in glands 30 to 50 g. The rate of positive sextant biopsy simulation was lower in glands greater than 50 g than in glands 50 g or less (48% versus 67%, P <0.03). Smaller cancers were much less likely to be detected in the simulations. The simulation detection rate for cancers 0.5 cc or less was 18% (6 of 33), compared with a detection rate of 73% (107 of 147) for cancers greater than 0.5 cc (P <0.00001). Conclusions. The observed lower cancer detection rate in large glands is a result of the higher proportion of low-volume cancers in these glands. This suggests that large prostates are more likely to be biopsied because of an elevated prostate-specific antigen value resulting from benign elements of the gland and not from a significant cancer. Increasing the number of cores solely to compensate for increased prostate size risks a disproportionate increased detection of small-volume tumors with a low clinical likelihood of progression. (C) 1999, Elsevier Science Inc. All rights reserved.
引用
收藏
页码:764 / 768
页数:5
相关论文
共 16 条
  • [1] PROSTATE-SPECIFIC ANTIGEN AND PROSTATE-GLAND VOLUME - CORRELATION AND CLINICAL-APPLICATION
    BABAIAN, RJ
    FRITSCHE, HA
    EVANS, RB
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1990, 4 (02) : 135 - 137
  • [2] TUMOR VOLUME AND PROSTATE-SPECIFIC ANTIGEN - IMPLICATIONS FOR EARLY DETECTION AND DEFINING A WINDOW OF CURABILITY
    BABAIAN, RJ
    TRONCOSO, P
    STEELHAMMER, LC
    LLORETATRULL, J
    RAMIREZ, EI
    [J]. JOURNAL OF UROLOGY, 1995, 154 (05) : 1808 - 1812
  • [3] Comparative analysis of prostate specific antigen and its indexes in the detection of prostate cancer
    Babaian, RJ
    Kojima, M
    Ramirez, EI
    Johnston, D
    [J]. JOURNAL OF UROLOGY, 1996, 156 (02) : 432 - 437
  • [4] HOW TO USE PROSTATE-SPECIFIC ANTIGEN IN THE EARLY DETECTION OR SCREENING FOR PROSTATIC-CARCINOMA
    BRAWER, MK
    [J]. CA-A CANCER JOURNAL FOR CLINICIANS, 1995, 45 (03) : 148 - 164
  • [5] Optimization of prostate biopsy strategy using computer based analysis
    Chen, ME
    Troncoso, P
    Johnston, DA
    Tang, K
    Babaian, RJ
    [J]. JOURNAL OF UROLOGY, 1997, 158 (06) : 2168 - 2175
  • [6] The definition and preoperative prediction of clinically insignificant prostate cancer
    Dugan, JA
    Bostwick, DG
    Myers, RP
    Qian, JQ
    Bergstralh, EJ
    Oesterling, JE
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 275 (04): : 288 - 294
  • [7] PATHOLOGICAL AND CLINICAL FINDINGS TO PREDICT TUMOR EXTENT OF NONPALPABLE (STAGE-T1C) PROSTATE-CANCER
    EPSTEIN, JI
    WALSH, PC
    CARMICHAEL, M
    BRENDLER, CB
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (05): : 368 - 374
  • [8] Distinguishing clinically important from unimportant prostate cancers before treatment: Value of systematic biopsies
    Goto, Y
    Ohori, M
    Arakawa, A
    Kattan, MW
    Wheeler, TM
    Scardino, PT
    [J]. JOURNAL OF UROLOGY, 1996, 156 (03) : 1059 - 1063
  • [9] Diagnosis of "suspicious for malignancy" in prostate biopsies: Predictive value for cancer
    Iczkowski, KA
    Bassler, TJ
    Schwob, VS
    Bassler, IC
    Kunnel, BS
    Orozco, RE
    Bostwick, DG
    [J]. UROLOGY, 1998, 51 (05) : 749 - 757
  • [10] Outcome of sextant biopsy according to gland volume
    Karakiewicz, PI
    Bazinet, M
    Aprikian, AG
    Trudel, C
    Aronson, S
    Nachabe, M
    Peloquint, F
    Dessureault, J
    Goyal, MS
    Begin, LR
    Elhilali, MM
    [J]. UROLOGY, 1997, 49 (01) : 55 - 59