Contraction stress of flowable composite materials and their efficacy as stress-relieving layers

被引:114
作者
Braga, RR
Hilton, TJ
Ferracane, JL
机构
[1] FOUSP, Dept Mat Dent, BR-05508900 Sao Paulo, Brazil
[2] Oregon Hlth & Sci Univ, Sch Dent, Dept Biomat & Biomech, Portland, OR USA
关键词
D O I
10.14219/jada.archive.2003.0258
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. The authors compared the polymerization contraction stress produced by flowable resin-based composites with stress values produced by nonflowable composites. They also measured the stress reduction produced by placing a precured layer of flowable composite under a nonflowable composite. Methods. The authors first tested four flowable and six nonflowable composite materials for contraction stress in a tensiometer. In the second part of the study they applied a 1.4-millimeter-thick layer of flowable composite or unfilled resin and precured it in the test apparatus to assess the stress relief produced by a low-modulus material during light curing of a subsequent layer of highly filled composite. Flexural moduli of the precured materials were determined via a three-point bending test. Results. The stress values ranged between 6.04 and 9.10 megapascals. The authors found no significant differences in stress between flowable and nonflowable composites. Microfilled composites produced lower contraction stress than did hybrids. The flexural modulus of the flowable composites varied between 4.1 and 8.2 GPa. Regarding the effect of a precured layer of composite on contraction stress, the authors observed significant reductions with only one of the flowable materials and with the unfilled resin. Conclusions. The flowable composites produced stress levels similar to those of nonflowable materials. Most of the flowable materials tested did not produce significant stress reductions when used under a nonflowable composite. Clinical Implications. Using a flowable resin-based composite as a restorative material is not likely to reduce the effects of polymerization stress. When used in a thin layer under a nonflowable composite, the stress reduction depended on the elastic modulus of the lining material.
引用
收藏
页码:721 / 728
页数:8
相关论文
共 34 条
[11]   RELAXATION OF POLYMERIZATION CONTRACTION STRESSES BY FLOW IN DENTAL COMPOSITES [J].
DAVIDSON, CL ;
DEGEE, AJ .
JOURNAL OF DENTAL RESEARCH, 1984, 63 (02) :146-148
[12]  
Estafan D, 2000, AM J DENT, V13, P192
[13]   SETTING STRESS IN COMPOSITE RESIN IN RELATION TO CONFIGURATION OF THE RESTORATION [J].
FEILZER, AJ ;
DEGEE, AJ ;
DAVIDSON, CL .
JOURNAL OF DENTAL RESEARCH, 1987, 66 (11) :1636-1639
[14]  
Ferdianakis K, 1998, J Clin Pediatr Dent, V22, P221
[15]  
FERRACANE JL, IN PRESS AM J DENT
[16]  
Fruits TJ, 2002, QUINTESSENCE INT, V33, P205
[17]  
Hilton T.J., 2001, J DENT RES, V80, P589
[18]  
*INT ORG STAND, 2000, ISOFDIS4049
[19]   The new posterior resins and a simplified placement technique [J].
Jackson, RD ;
Morgan, M .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2000, 131 (03) :375-383
[20]  
Jain P, 2000, AM J DENT, V13, P235