Detection and characterization of focal liver lesions using superparamagnetic iron oxide-enhanced magnetic resonance imaging: comparison between ferumoxides-enhanced T1-weighted imaging and delayed-phase gadolinium-enhanced T1-weighted imaging

被引:18
作者
Takahama, K [1 ]
Amano, Y [1 ]
Hayashi, H [1 ]
Ishihara, M [1 ]
Kumazaki, T [1 ]
机构
[1] Nippon Med Coll, Dept Radiol, Bunkyo Ku, Tokyo 1138603, Japan
关键词
magnetic resonance imaging; superparamagnetic iron oxide; liver; metastasis; cyst;
D O I
10.1007/s00261-002-0064-9
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Double contrast magnetic resonance (MR) imaging using superparamagnetic iron oxide (SPIO) and gadolinium (Gd) is performed to detect and characterize focal liver lesions. However, this technique is a costly and lengthy process. The purpose of this study was to determine the usefulness of SPIO-enhanced MR imaging including SPIO-enhanced T1-weighted imaging in diagnosing focal liver lesions. Methods: Eighty-four focal liver lesions were examined with a 1.5-T MR unit. Transverse precontrast T1- and T2-weighted images and SPIO (ferumoxides)-enhanced T1- and T2-weighted images were obtained, followed by Gd-enhanced T1-weighted imaging. The Gd set (i.e., precontrast T1- and T2-weighted and delayed-phase gadolinium-enhanced T1-weighted images) and ferumoxides set (i.e., precontrast T1- and ferumoxides-enhanced T1- and T2-weighted images) were reviewed by two independent readers. Results: More lesions were detected from the ferumoxides set than from the Gd set. Ferumoxides-enhanced T1-weighted imaging showed enhancement patterns of the lesions similar to those of delayed-phase Gd-enhanced T1-weighted imaging. The diagnoses of hepatic metastasis and cyst by the ferumoxides set were similar to those by the Gd set. However, a dynamic study may be inevitable for the diagnosis of hepatocellular carcinoma and hemangioma. Conclusion: The ferumoxides set was useful for the detection of focal hepatic lesions. Ferumoxides-enhanced T1-weighted imaging may replace delayed-phase gadolinium-enhanced T1-weighted imaging in the diagnosis of hepatic metastasis and cysts.
引用
收藏
页码:525 / 530
页数:6
相关论文
共 20 条
  • [1] LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING
    BELLIN, MF
    ZAIM, S
    AUBERTON, E
    SARFATI, G
    DURON, JJ
    KHAYAT, D
    GRELLET, J
    [J]. RADIOLOGY, 1994, 193 (03) : 657 - 663
  • [2] IRON-OXIDE ENHANCED MR-IMAGING OF THE LIVER AND SPLEEN - REVIEW OF THE 1ST-5 YEARS
    FERRUCCI, JT
    STARK, DD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) : 943 - 950
  • [3] DETECTION OF HEPATIC METASTASES - COMPARISON OF CONTRAST-ENHANCED CT, UNENHANCED MR IMAGING, AND IRON-OXIDE ENHANCED MR IMAGING
    FRETZ, CJ
    STARK, DD
    METZ, CE
    ELIZONDO, G
    WEISSLEDER, R
    SHEN, JH
    WITTENBERG, J
    SIMEONE, J
    FERRUCCI, JT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) : 763 - 770
  • [4] BENIGN HEPATOCELLULAR TUMORS - MRI AFTER SUPERPARAMAGNETIC IRON-OXIDE ADMINISTRATION
    GRANDIN, C
    VANBEERS, BE
    ROBERT, A
    GIGOT, JF
    GEUBEL, A
    PRINGOT, J
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (03) : 412 - 418
  • [5] GRANGIER C, J COMPUT ASSIST TOMO
  • [6] PHASE-I CLINICAL-EVALUATION OF GD-EOB-DTPA AS A HEPATOBILIARY MR CONTRAST AGENT - SAFETY, PHARMACOKINETICS, AND MR-IMAGING
    HAMM, B
    STAKS, T
    MUHLER, A
    BOLLOW, M
    TAUPITZ, M
    FRENZEL, T
    WOLF, KJ
    WEINMANN, HJ
    LANGE, L
    [J]. RADIOLOGY, 1995, 195 (03) : 785 - 792
  • [7] ENHANCEMENT OF TUMOR-LIVER CONTRAST-TO-NOISE RATIO WITH GADOBENATE DIMEGLUMINE IN MR-IMAGING OF RATS
    KREFT, BP
    TANIMOTO, A
    STARK, DD
    BABA, Y
    ZHAO, LH
    CHEN, JT
    COMPTON, CC
    FINN, JP
    CAVAGNA, FM
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01): : 41 - 49
  • [8] Low R N, 2001, Magn Reson Imaging Clin N Am, V9, P717
  • [9] Nakayama M, 2000, J MAGN RESON IMAGING, V11, P647, DOI 10.1002/1522-2586(200006)11:6<647::AID-JMRI11>3.3.CO
  • [10] 2-6