First certified reference material for cystatin C in human serum ERM-DA471/IFCC
被引:324
作者:
Grubb, Anders
论文数: 0引用数: 0
h-index: 0
机构:
Univ Lund Hosp, Dept Clin Chem, S-22185 Lund, SwedenCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements IRMM, B-2440 Geel, Belgium
Grubb, Anders
[2
]
Blirup-Jensen, Soren
论文数: 0引用数: 0
h-index: 0
机构:
Univ Lund Hosp, Dept Clin Chem, S-22185 Lund, SwedenCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements IRMM, B-2440 Geel, Belgium
Blirup-Jensen, Soren
[2
]
Lindstrom, Veronica
论文数: 0引用数: 0
h-index: 0
机构:
Univ Lund Hosp, Dept Clin Chem, S-22185 Lund, SwedenCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements IRMM, B-2440 Geel, Belgium
Lindstrom, Veronica
[2
]
Schmidt, Camilla
论文数: 0引用数: 0
h-index: 0
机构:
Univ Lund Hosp, Dept Clin Chem, S-22185 Lund, SwedenCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements IRMM, B-2440 Geel, Belgium
Schmidt, Camilla
[2
]
Althaus, Harald
论文数: 0引用数: 0
h-index: 0
机构:
Siemens Healthcare Diagnost Prod GmbH, Marburg, GermanyCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements IRMM, B-2440 Geel, Belgium
Althaus, Harald
[3
]
Zegers, Ingrid
论文数: 0引用数: 0
h-index: 0
机构:
Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements IRMM, B-2440 Geel, BelgiumCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements IRMM, B-2440 Geel, Belgium
Zegers, Ingrid
[1
]
机构:
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements IRMM, B-2440 Geel, Belgium
[2] Univ Lund Hosp, Dept Clin Chem, S-22185 Lund, Sweden
The IFCC Working Group for the Standardisation of Cystatin C (WG-SCC), in collaboration with the Institute for Reference Materials and Measurements (IRMM), announces the availability of the new certified reference material ERM-DA471/IFCC. The material was characterised using a pure protein primary reference preparation (PRP) as calibrant. The PRP was prepared from recombinant cystatin C, and its concentration measured using dry mass determination. The characterisation of ERM-DA471/IFCC was performed by particle enhanced immuno-nephelometry, particle enhanced immuno-turbidimetry, and enzyme amplified single radial immuno-diffusion. The certified cystatin C mass concentration in ERM-DA471/IFCC, if reconstituted according to the specified procedure, is 5.48 mg/L, the expanded uncertainty (k=2) being 0.15 mg/L. Clin Chem Lab Med 2010;48:1619-21.