Feasibility study of time-intensity-based blood flow measurements using deconvolution

被引:11
作者
Yeh, CK [1 ]
Wang, SW [1 ]
Li, PC [1 ]
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
基金
美国国家科学基金会;
关键词
blood flow estimation; deconvolution; effective mixing volume; time-intensity curve; ultrasonic contrast agent;
D O I
10.1177/016173460102300202
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasonic contrast agents have been used to enhance the acoustic backscattered intensity of blood and to assist the assessment of blood flow parameters. One example is the time-intensity method based on the indicator-dilution theory. In this case, a mixing chamber model can be employed to describe the concentration or the contrast agent as a function of time. By measuring the time intensities at both the input and output of the blood mixing chamber. blood flow information can be obtained if proper deconvolution techniques are applied. Note that most deconvolution techniques assume a linear and time invariant (LTI) system for the mixing of the contrast agent with blood. In this paper, the hypothesis that a blood mixing chamber is an LTI system was tested. Several aspects were Studied. One aspect was the linear relationship between the concentration of the contrast agent and the backscattered intensity. The other aspect was the dependence of the derived time constants on the concentration. The concept of an effective mixing volume was also introduced and evaluated. Finally, the input and the output time constants were measured and compared to theory under the LTI assumption, Extensive experiments were performed. Two in vitro flow models were constructed and two contrast agents were use(]. Results indicated that the LTI assumption does not hold and quantitative flow estimation is generally not possible. Nonetheless, the indicator-dilution theory can still be applied if only relative measurements of the flow rate are required.
引用
收藏
页码:90 / 105
页数:16
相关论文
共 20 条
[2]   DECONVOLUTION OF TRACER AND DILUTION DATA USING THE WIENER FILTER [J].
BATES, JHT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (12) :1262-1266
[3]   A mathematical model for the assessment of hemodynamic parameters using quantitative contrast echocardiography [J].
Chen, XC ;
Schwarz, KQ ;
Phillips, D ;
Steinmetz, SD ;
Schlief, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (06) :754-765
[4]   Quantification of flow rates using harmonic grey-scale imaging and an ultrasound contrast agent:: an in vitro and in vivo study [J].
Claassen, L ;
Seidel, G ;
Algermissen, C .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01) :83-88
[5]   DIGITAL ANGIOGRAPHIC IMPULSE-RESPONSE ANALYSIS OF REGIONAL MYOCARDIAL PERFUSION - LINEARITY, REPRODUCIBILITY, ACCURACY, AND COMPARISON WITH CONVENTIONAL INDICATOR DILUTION CURVE PARAMETERS IN PHANTOM AND CANINE MODELS [J].
EIGLER, NL ;
PFAFF, JM ;
ZEIHER, A ;
WHITING, JS ;
FORRESTER, JS .
CIRCULATION RESEARCH, 1989, 64 (05) :853-866
[6]  
FRED SG, 1962, CIRC RES, V10, P429
[7]   A DECONVOLUTION METHOD FOR EVALUATING INDICATOR-DILUTION CURVES [J].
GOBBEL, GT ;
FIKE, JR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (11) :1833-1854
[8]  
GOLDBERG BB, 1997, ULTRASOUND CONTRAST, P21
[9]  
Heidenreich P A, 1993, J Am Soc Echocardiogr, V6, P51
[10]   A PERFUSION PHANTOM FOR THE EVALUATION OF ULTRASOUND CONTRAST AGENTS [J].
HINDLE, AJ ;
PERKINS, AC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (03) :309-314