Diffraction-free acoustic detection for optoacoustic depth profiling of tissue using an optically transparent polyvinylidene fluoride pressure transducer operated in backward and forward mode

被引:22
作者
Jaeger, M [1 ]
Niederhauser, JJ [1 ]
Hejazi, M [1 ]
Frenz, M [1 ]
机构
[1] Univ Bern, Inst Appl Phys, CH-3012 Bern, Switzerland
关键词
photoacoustics; pressure transducer; signal detection; stress analysis; acoustic diffraction; medical imaging;
D O I
10.1117/1.1891443
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An optoacoustic detection method suitable for depth profiling of optical absorption of layered or continuously varying tissue structures is presented. Detection of thermoelastically induced pressure transients allows reconstruction of optical properties of the sample to a depth of several millimeters with a spatial resolution of 24 mu m. Acoustic detection is performed using a specially designed piezoelectric transducer, which is transparent for optical radiation. Thus, ultrasonic signals can be recorded at the same position the tissue is illuminated. Because the optoacoustical sound source is placed in the pulsed-acoustic near field of the pressure sensor, signal distortions commonly associated with acoustical diffraction are eliminated. Therefore, the acoustic signals mimic exactly the depth profile of the absorbed energy. This is illustrated by imaging the absorption profile of a two-layered sample with different absorption coefficients, and of a dye distribution while diffusing into a gelatin phantom. (c) 2005 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:7
相关论文
共 26 条
[1]   CHARACTERISTICS OF A PVDF MEMBRANE HYDROPHONE FOR USE IN THE RANGE 1-100 MHZ [J].
BACON, DR .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1982, 29 (01) :18-25
[2]   Extrinsic optical-fiber ultrasound sensor using a thin polymer film as a low-finesse Fabry-Perot interferometer [J].
Beard, PC ;
Mills, TN .
APPLIED OPTICS, 1996, 35 (04) :663-675
[3]   Characterization of post mortem arterial tissue using time-resolved photoacoustic spectroscopy at 436, 461 and 532 nm [J].
Beard, PC ;
Mills, TN .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01) :177-198
[4]   Optical fiber photoacoustic-photothermal probe [J].
Beard, PC ;
Perennes, F ;
Draguioti, E ;
Mills, TN .
OPTICS LETTERS, 1998, 23 (15) :1235-1237
[5]   Laser-generated cavitation in absorbing liquid induced by acoustic diffraction [J].
Frenz, M ;
Paltauf, G ;
SchmidtKloiber, H .
PHYSICAL REVIEW LETTERS, 1996, 76 (19) :3546-3549
[6]   Three-dimensional photoacoustic imaging of blood vessels in tissue [J].
Hoelen, CGA ;
de Mul, FFM ;
Pongers, R ;
Dekker, A .
OPTICS LETTERS, 1998, 23 (08) :648-650
[7]  
Karabutov A. A., 1995, Moscow University Physics Bulletin, V50, P25
[8]   Backward mode detection of laser-induced wide-band ultrasonic transients with optoacoustic transducer [J].
Karabutov, AA ;
Savateeva, EV ;
Podymova, NB ;
Oraevsky, AA .
JOURNAL OF APPLIED PHYSICS, 2000, 87 (04) :2003-2014
[9]  
Karabutov AA, 1996, APPL PHYS B-LASERS O, V63, P545
[10]   Optoacoustic sensor head for depth profiling [J].
Kopp, C ;
Niessner, R .
APPLIED PHYSICS B-LASERS AND OPTICS, 1999, 68 (04) :719-725