An unmediated hydrogen peroxide biosensor based on hemoglobin incorporated in a montmorillonite membrane

被引:32
作者
Fan, CH
Gao, QX
Zhu, DX
Wagner, G
Li, GX
机构
[1] Harvard Univ, Sch Med, Dept Biol Chem & Mol Pharmacol, Boston, MA 02115 USA
[2] Nanjing Univ, Dept Biochem, Nanjing 210093, Peoples R China
[3] Nanjing Univ, Natl Lab Pharmaceut Biotechnol, Nanjing 210093, Peoples R China
关键词
D O I
10.1039/b102873c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hemoglobin was incorporated in a montmorillonite membrane. Electrochemical and spectroscopic studies revealed that the electron transfer reactivity and peroxidase activity of the protein were both enhanced. Nevertheless, its structure was still maintained native-like in the membrane. An unmediated hydrogen peroxide biosensor was accordingly prepared. The calibration plot of this H2O2 sensor was linear in the range of 1.0 x 10(-6)-6.0 x 10(-4) mol L-1. The relative standard deviation was 3.1% for six successive determinations at a concentration of 1.0 x 10(-4) mol L-1. The detection limit was 6.0 x 10(-7) mol L-1. Possible interferences in real sample analyses are discussed.
引用
收藏
页码:1086 / 1089
页数:4
相关论文
共 44 条
[1]   Reactions of sperm whale myoglobin with hydrogen peroxide - Effects of distal pocket mutations on the formation and stability of the ferryl intermediate [J].
Alayash, AI ;
Ryan, BAB ;
Eich, RF ;
Olson, JS ;
Cashon, RE .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1999, 274 (04) :2029-2037
[2]   Reactions of complex metalloproteins studied by protein-film voltammetry [J].
Armstrong, FA ;
Heering, HA ;
Hirst, J .
CHEMICAL SOCIETY REVIEWS, 1997, 26 (03) :169-179
[3]  
BARD AJ, 1984, ELECTROANALYTICAL CH
[4]   Application of iron-tetrasulfonatophthalocyanine as a new mimetic peroxidase in the determination of hydrogen peroxide with p-hydroxyphenylpropionic acid as a substrate [J].
Chen, QY ;
Li, DH ;
Zhu, QZ ;
Zheng, H ;
Xu, JG .
ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) :175-182
[5]  
FAN C, IN PRESS ANAL CHEM
[6]  
Fan CH, 2000, ELECTROANAL, V12, P1156, DOI 10.1002/1521-4109(200010)12:14<1156::AID-ELAN1156>3.0.CO
[7]  
2-4
[8]   A reagentless nitric oxide biosensor based on hemoglobin-DNA films [J].
Fan, CH ;
Li, GX ;
Zhu, JQ ;
Zhu, DX .
ANALYTICA CHIMICA ACTA, 2000, 423 (01) :95-100
[9]   An unmediated hydrogen peroxide sensor based on a hemoglobin-SDS film modified electrode [J].
Fan, CH ;
Suzuki, I ;
Chen, Q ;
Li, GX ;
Anzai, J .
ANALYTICAL LETTERS, 2000, 33 (13) :2631-2644
[10]   Direct electrochemical characterization of the interaction between haemoglobin and nitric oxide [J].
Fan, CH ;
Chen, XC ;
Li, GX ;
Zhu, JQ ;
Zhu, DX ;
Scheer, H .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2000, 2 (19) :4409-4413