Automatic detection of stent struts with thick neointimal growth in intravascular optical coherence tomography image sequences

被引:31
作者
Xu, Chenyang [1 ]
Schmitt, Joseph M. [1 ]
Akasaka, Takashi [2 ]
Kubo, Takashi [2 ]
Huang, Kun [3 ]
机构
[1] Lightlab Imaging Inc, Westford, MA 01886 USA
[2] Wakayama Med Univ, Dept Cardiovasc Med, Wakayama, Japan
[3] Ohio State Univ, Dept Biomed Informat, Columbus, OH 43210 USA
基金
日本学术振兴会;
关键词
BALLOON ANGIOPLASTY; PLACEMENT;
D O I
10.1088/0031-9155/56/20/010
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
To assist cardiologists investigating neointimal tissue growth on stents during follow-up with optical coherence tomography (OCT), we developed an automatic algorithm to locate deeply buried stent struts and to quantify the restenosis burden. The technique is based on an improved steerable filter for computing the local ridge strength and orientation. It also uses an ellipsoid fitting algorithm and continuity criteria to obtain globally optimal stent localization. The restenosis burden calculations were compared to manual assessment of OCT coronary artery image data obtained from in vivo human clinical studies. Compared to manual assessment by expert readers, the algorithm operated with > 97% accuracy in the measurement of mean and maximum restenosis burden. The results indicated that the technique yielded comparable accuracy in measuring restenosis burden, and significantly reduced user interaction time.
引用
收藏
页码:6665 / 6675
页数:11
相关论文
共 14 条
[1]
Antman EM, 2008, J AM COLL CARDIOL, V51, P2028, DOI [10.1016/j.jacc.2008.04.002, 10.1016/j.jacc.2007.10.001]
[2]
Current and future developments in intracoronary optical coherence tomography imaging [J].
Barlis, Peter ;
Schmitt, Joseph M. .
EUROINTERVENTION, 2009, 4 (04) :529-533
[3]
An automatic algorithm for detecting stent endothelialization from volumetric optical coherence tomography datasets [J].
Bonnema, Garret T. ;
Cardinal, Kristen O'Halloran ;
Williams, Stuart K. ;
Barton, Jennifer K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (12) :3083-3098
[4]
A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[5]
Reproducibility of quantitative optical coherence tomography for stent analysis [J].
Gonzalo, Nieves ;
Garcia-Garcia, Hector M. ;
Serruys, Patrick W. ;
Commissaris, Koen H. ;
Bezerra, Hiram ;
Gobbens, Pierre ;
Costa, Marco ;
Regar, Evelyn .
EUROINTERVENTION, 2009, 5 (02) :224-232
[6]
Optical coherence tomography: High resolution intravascular imaging to evaluate vascular healing after coronary stenting [J].
Guagliumi, Giulio ;
Sirbu, Vasile .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (02) :237-247
[7]
HALIR R, 1998, WSCG 98 6 INT C CENT
[8]
Design of steerable filters for feature detection using Canny-like criteria [J].
Jacob, M ;
Unser, M .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2004, 26 (08) :1007-1019
[9]
ANGIOGRAPHIC FOLLOW-UP AFTER PLACEMENT OF A SELF-EXPANDING CORONARY-ARTERY STENT [J].
SERRUYS, PW ;
STRAUSS, BH ;
BEATT, KJ ;
BERTRAND, ME ;
PUEL, J ;
RICKARDS, AF ;
MEIER, B ;
GOY, JJ ;
VOGT, P ;
KAPPENBERGER, L ;
SIGWART, U .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (01) :13-17
[10]
A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SERRUYS, PW ;
DEJAEGERE, P ;
KIEMENEIJ, F ;
MACAYA, C ;
RUTSCH, W ;
HEYNDRICKX, G ;
EMANUELSSON, H ;
MARCO, J ;
LEGRAND, V ;
MATERNE, P ;
BELARDI, J ;
SIGWART, U ;
COLOMBO, A ;
GOY, JJ ;
VANDENHEUVEL, P ;
DELCAN, J ;
MOREL, MA .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :489-495